SC16C550BIB48 NXP Semiconductors, SC16C550BIB48 Datasheet - Page 25

UART, 16BYTE FIFO, 16C550, LQFP48

SC16C550BIB48

Manufacturer Part Number
SC16C550BIB48
Description
UART, 16BYTE FIFO, 16C550, LQFP48
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C550BIB48

No. Of Channels
1
Data Rate
3Mbps
Supply Voltage Range
2.25V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
48
Svhc
No SVHC (18-Jun-2010)
Operating
RoHS Compliant
Uart Features
Automatic Hardware Flow Control, Software Selectable Baud Rate Generator
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C550BIB48
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
SC16C550BIB48,128
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C550BIB48,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C550BIB48,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
SC16C550B_5
Product data sheet
7.6 Modem Control Register (MCR)
This register controls the interface with the modem or a peripheral device.
Table 19.
Bit
7
6
5
4
3
2
1
0
Symbol
MCR[7]
MCR[6]
MCR[5]
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
Modem Control Register bits description
Description
reserved; set to ‘0’
reserved; set to ‘0’
Auto flow control enable.
Loopback. Enable the local loopback mode (diagnostics). In this mode the
transmitter output (TX) and the receiver input (RX), CTS, DSR, DCD, and
RI are disconnected from the SC16C550B I/O pins. Internally the modem
data and control pins are connected into a loopback data configuration
(see
remain fully operational. The Modem Control Interrupts are also
operational, but the interrupts’ sources are switched to the lower four bits
of the Modem Control. Interrupts continue to be controlled by the IER
register.
OUT2. Used to control the modem DCD signal in the loopback mode.
OUT1. This bit is used in the Loopback mode only. In the loopback mode,
this bit is used to write the state of the modem RI interface signal via
OUT1.
RTS
DTR
Rev. 05 — 1 October 2008
logic 0 = disable loopback mode (normal default condition)
logic 1 = enable local loopback mode (diagnostics)
logic 0 = OUT2 is at logic 1. In the loopback mode, sets OUT2 (DCD)
internally to a logic 1.
logic 1 = OUT2 is at logic 0. In the loopback mode, sets OUT2 (DCD)
internally to a logic 0.
logic 0 = force RTS output to a logic 1 (normal default condition)
logic 1 = force RTS output to a logic 0
logic 0 = force DTR output to a logic 1 (normal default condition)
logic 1 = force DTR output to a logic 0
Figure
11). In this mode, the receiver and transmitter interrupts
5 V, 3.3 V and 2.5 V UART with 16-byte FIFOs
SC16C550B
© NXP B.V. 2008. All rights reserved.
25 of 48