3UG4622-1AW30 SIEMENS, 3UG4622-1AW30 Datasheet - Page 29

RELAY, MONITOR, 22.5MM

3UG4622-1AW30

Manufacturer Part Number
3UG4622-1AW30
Description
RELAY, MONITOR, 22.5MM
Manufacturer
SIEMENS
Series
3UG46r
Datasheet

Specifications of 3UG4622-1AW30

Contact Configuration
SPCO
Power Consumption
4VA
Supply Voltage Max
240VAC
Contact Current Max
3A
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
230V
External Depth
86mm
Coil Frequency Max
60Hz
Coil Operating Frequency Min
50Hz
Technical specifications
Permissible ambient temperature
Permissible storage temperature
Installation altitude above sea level
Degree of protection (acc. to IEC 60529)
Shock resistance (sine pulse)
Mounting position
Mounting
• Max. set current I
• Max. set current I
EMC interference immunity
• Conducted interference, burst acc. to IEC 61000-4-4
• Conducted interference, surge acc. to IEC 61000-4-5
• Electrostatic discharge acc. to IEC 61000-4-2
• Field-related interference acc. to IEC 61000-4-3
EMC interference emission
Safe isolation
(product version 12 upwards, start of delivery 01/2000)
Displays
• Green "Ready" LED
• Green "BUS" LED
• Red "General Fault" LED
Test/Reset buttons
System interfaces
PROFIBUS DP interface
Main circuits
Rated insulation voltage U
(with pollution degree 3)
• For uninsulated conductors (3UF5 001 to 3UF5 021)
• For insulated conductors (3UF5 001 to 3UF5 021)
• For uninsulated and insulated conductors
Rated impulse withstand voltage U
• 3UF5 001 to 3UF5 021
• 3UF5 031 to 3UF5 051
Rated frequency
Type of current
Short-circuit protection
Diameters of feed-through openings
(max. I
• Devices with max. set current I
• Devices with max. set current I
• Devices with max. set current I
Busbar connections
• Current range
• Tightening torque
• Finely stranded with cable lug
• Stranded with cable lug
Shared data of basic units/expansion units/
expansion modules/operator panels
Basic units
(3UF5 031 to 3UF5 051)
e
= 100 A)
e
e
ˆ 100 A
> 100 A
SIMOCODE 3UF Motor Management and Control Devices
i
e
e
e
ˆ 25 A
ˆ 100 A
> 100 A
imp
°C
°C
m
g/ms
kV
kV
kV
V/m
V
V
V
kV
kV
Hz
mm
mm
A
Nm
mm
mm
2
2
-25 ... +60
-40 ... +80
ˆ 2000
IP20 max. set current I
IP00 max. set current I
10/5
Any
Snap-on mounting onto 35 mm standard mounting rail or
screw fixing with push-in lugs
Screw fixing directly onto contactor or screw fixing
2 (corresponds to degree of severity 3)
2 (corresponds to degree of severity 3)
8 (corresponds to degree of severity 3)
10 (corresponds to degree of severity 3)
Limit class B acc. to EN 55011 (VDE 0875 Part 11)
All electric circuits in SIMOCODE-DP are safely isolated from each other,
i.e. they are designed with double leakage paths and clearances
Power circuit from the control/electronic circuits:
Safe isolation up to 690 V or 1000 V between control and electronic circuits
One below the other: Safe isolation up to 300 V
Observe notes of test report "Safe Isolation" No. 1610a.
Continuous light: "Ready"
Off: "No control supply voltage" or "Function test not OK; device is disabled"
Continuous light: "Bus operation"
Continuous light/blinklight: "Feeder fault", e.g. overload tripping
By pressing the Test/Reset button, the device can be reset following a trip or its
functions can be tested
RS 232 for connecting the expansion module, operator panel or PC
RS 485 for connecting the PROFIBUS DP line using terminals (conductor cross-
sections as for auxiliary contacts) or 9-pole SUB D socket
690
1000
1000
6
8
50/60
Three-phase current
See table Short-circuit protection with fuses for motor feeders, page 7/31
10
15
Design with connecting bars
50 ... 205
M 8: 10 ... 14
35 ... 95
50 ... 120
e
e
ˆ 100 A;
> 100 A
125 ... 500
M 10: 14 ... 24
50 ... 240
70 ... 240
motor protection and control devices
Siemens LV 1 T · 2006
SIMOCODE-DP 3UF5
200 ... 820
M 10: 14 ... 24
M 12: 20 ... 35
50 ... 240
70 ... 240
7/29

Related parts for 3UG4622-1AW30