3UG4513-1BR20 SIEMENS, 3UG4513-1BR20 Datasheet - Page 4

SSR, DIN RAIL, 690VAC, 690VAC, 5A

3UG4513-1BR20

Manufacturer Part Number
3UG4513-1BR20
Description
SSR, DIN RAIL, 690VAC, 690VAC, 5A
Manufacturer
SIEMENS
Datasheet

Specifications of 3UG4513-1BR20

Control Voltage Range
160V To 690V
Operating Voltage Range
200Vrms To 690Vrms
Load Current
5A
Control Voltage Type
AC
Relay Terminals
Screw
Length/height, External
82mm
External Width
22.5mm
Load Voltage Max
400V
Load Current Rms Max
5A
Rohs Compliant
Yes
External Depth
86mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3UG Monitoring Relays for Electrical and Additional Measurements
Line monitoring
Technical specifications
1)
Rated control supply voltage U
Rated frequency
Rated power, typical
• At 230 V AC
• At 400 V AC
• At 460 V AC
Width
RESET
Principle of operation
Availability time after application of U
Response time on reaching a switching threshold
Adjustable tripping delay time
Adjustable ON-delay time
Mains buffering time, min.
Rated insulation voltage U
Degree of pollution 3
Overvoltage category III according to VDE 0110
Rated impulse withstand voltage
Permissible ambient temperature
• During operation
• During storage
EMC tests
Degree of protection
• Enclosures
• Terminals
Vibration resistance according to IEC 60068-2-6
Shock resistance according to IEC 60068 Part 2-27
Conductor cross-section
• Screw terminals
• Spring-loaded terminals
Measuring range AC 50/60 Hz rms value
Setting range
Measuring accuracy
Repeat accuracy at constant parameters
Setting accuracy
Accuracy of digital display
Deviations for temperature fluctuations
Hysteresis for voltage
Hysteresis for unbalance
Deviation for frequency fluctuation
General data
Measuring circuit
7/64
- Solid
- Finely stranded with end sleeve
- AWG conductors, solid or stranded
- Tightening torque
- Solid
- Finely stranded, with end sleeves according to
- Finely stranded
- AWG conductors, solid or stranded
Note: This is a Class A product. In the household environment this device
may cause radio interference. In this case the user must introduce suitable
measures.
DIN 46228
Monitoring Relays
1)
Siemens LV 1 T · 2007
i
s
s
V
Hz
W/VA
W/VA
W/VA
mm
ms
ms
s
s
ms
V
kV
°C
°C
Hz/mm 1-6/15; 6-500, 20 m/s
g/ms
mm
mm
AWG
Nm
mm
mm
mm
AWG
V
V
%
%
%/°C
V
%
%
2
2
2
2
2
3UG45 11-
..N20
160 … 260
50/60
2/4
--
--
22.5
Auto-RESET
Closed-circuit
200
Max. 450
--
--
10
690
6
-25 … +60
-40 … +85
IEC 60947-1/ IEC 61000-6-2 / IEC 61000-6-4
IP40
IP20
15/11
M3 (standard screwdriver size 2 and Pozidriv 2)
1 x (0.5 ... 4) / 2 x (0.5 ... 2.5)
1 x (0.5 ... 2.5) / 2 x (0.5 ... 1.5)
2 x (20 ... 14)
0.8 … 1.2
2 x (0.25 ... 1.5)
2 x (0.25 ... 1.5)
2 x (0.25 ... 1.5)
2 x (24 ... 16)
160 ... 260
--
--
--
--
--
--
--
--
© Siemens AG 2007
3UG45 11-
..P20
320 … 500
--
2/8
--
320 ... 500
2
3UG45 11-
..Q20
420 … 690
--
--
2/8
420 ... 690
3UG45 12
160 … 690
2/2.5
2/3.5
2/4
1000
30
160 ... 690
3UG45 13
Automatic/manual
0.1 ... 20
200...690
±5
±1
– 10 %
referred to
set value
±0.1
5 % of set
value
±1 %
3UG46 14
Closed-circuit, open-circuit
(3UG46 17/3UG46 18:
closed-circuit)
0.1 … 20
160...690
– 1 V
+/-1 digit
1 ... 20 V
2 % of limit
value
3UG46 15
3UG46 16
3UG46 17
3UG46 18
--
2 % of limit
value for
3UG46 17/
3UG46 18

Related parts for 3UG4513-1BR20