10250T3 EATON CUTLER HAMMER, 10250T3 Datasheet - Page 30

CONTACT BLOCK, 2NC, 6A, SCREW

10250T3

Manufacturer Part Number
10250T3
Description
CONTACT BLOCK, 2NC, 6A, SCREW
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of 10250T3

No. Of Poles
2
Contact Current Max
6A
Contact Voltage Ac Max
600V
Contact Voltage Dc Max
250V
Switch Terminals
Screw
For Use With
10250T Series Pushbuttons And Indicating Lights
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
47
47-30
Environmental Conditions
Terminal Markings
All rear of panel devices are marked with the circuit configu-
ration per CENELEC 50013 standards.
Table 47-29. Contact Blocks
Table 47-30. Lights Units
Contact Block Terminal Clamps
Circuit Configuration
Circuit Configuration
4A
Operating temperature:
-4° to +140°F (-20° to +60°C)
Storage temperature:
-40° to +176°F (-40° to +80°C)
Altitude: Up to 6562 feet (2000m)
Pollution degree (IEC 947-1): 3
Humidity: Maximum 95% RH @ 60°C
E22CB1, E22CB11, E22CB1E, E22B1 and E22B11 contact
blocks are marked with Direct Opening Action (DOA) Sym-
bol “ “ per IEC 60947-5-1, Annex K and NEMA ICS 5, Part
6. For Mechanical Operating Parameters, see Page 47-69.
E22CB1, E22CB11 and E22CB1E contact blocks will be
marked as Suitable for Isolation per IEC 60947-5-1.
Clamp type: Self-lifting
Screw type: Plus/minus, captive
Wire range: 18 to 12 AWG (0.75 to 4.0 mm
Fingerproof protection: IP2X
Tightening torque: 7 lb-in (0.8 Nm)
2
4
2
4
4
4
2
Pushbuttons & Indicating Lights
22.5 mm Heavy-Duty Watertight/Oiltight
E22 and EM22 Series, Technical Data and Specifications
X2
X1
X1
3A
1
3
1
3
3
3
1
X2
X1
X2
Description
1NC
1NO
1NO-1NC
2NO
1NO
Early Make
1NC
Late Break
Description
Full Voltage
Resistor
Transformer
2
For more information visit: www.eaton.com
)
Plunger
Color
Red
Green
White
Green
Black
Gray
Electrical Ratings
Table 47-31. Contact Block
Logic level contact blocks are UL A600, Q600 and IEC AC15,
DC13 rated and also have a minimum rating of 1 mA @ 5V DC.
Short Circuit Coordination to IEC/EN 60947-5-1
Electrical Life
Material
Meet or Exceed NEMA Contact Rating Designations A600 and Q600
Description
Make and emergency
interrupting capacity
(Amp)
Normal load break (Amp)
Thermal current (Amp)
Ratings do not apply to rotary cam switches, see Ratings Page 47-95.
A600, Q600 per UL 508
AC15, DC13 per IEC 60947-5-1
Impulse withstand voltage (Uimp): 4 kV
Rated conditional short circuit current: 1 kA
Fuse type: GE Power Controls TIA 10, Red Spot Type
gG, 10A, 660V AC, 460V DC, BS88-2, IEC 60269-2-1
AC15 durability
DC13 durability
Housing, bezel, mounting rings: Glass filled nylon
Metal bezels: Chrome plated brass
Internal seal: Nitrile rubber
Panel gasket: Nitrile rubber
Illuminated lenses: Polycarbonate
Buttons: Polyester or polycarbonate
Contacts: Silver
Terminals: Brass
120V, 6A – 1 x 10
24V, 4A – 0.15 x 10
660V, 0.1A – 0.5 x 10
6
A600 (AC) Volts
120
60
10
operations
6
6
operations
6
operations
240
30
10
3
480
15
10
1.5
600
12
10
1.2 0.55 0.27 0.1
Q600 (DC) Volts
125
0.55 0.27 0.1
2.5
250
2.5
CA08102001E
March 2008
440
2.5
600
0.1
0.1
2.5

Related parts for 10250T3