LISY300AL STMicroelectronics, LISY300AL Datasheet
LISY300AL
Specifications of LISY300AL
Related parts for LISY300AL
LISY300AL Summary of contents
Page 1
... Order code Temperature range (°C) LISY300AL LISY300ALTR May 2008 The LISY300AL has a full scale of ±300 °/s and is capable of measuring rates with bandwidth Hz. The LISY300AL is available in a plastic land grid array (LGA) package and can operate within a temperature range from -40 °C to +85 °C. ...
Page 2
... Block diagram and pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Mechanical and electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1 Mechanical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.2 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.3 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.4 Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.4.1 2.4.2 2.4.3 3 Application hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3.1 Soldering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4 Package information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2/13 Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Zero-rate level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Self-test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 LISY300AL ...
Page 3
... AMPLIFIER TRIMMING CIRCUITS NC GND GND NC CACT ANALOG OUTPUT NC Block diagram and pin description ACTIVE LOW-PASS FILTER SWITCHED CAPACITOR ANALOG OUTPUT LOW-PASS FILTER AUTOMATIC GAIN CONTROL PID control CLOCK PHASE GENERATOR Reserved 1 Reserved Reserved LISY300AL Reserved (TOP VIEW) Reserved Reserved PLL 3/13 ...
Page 4
... Power-down (logic 0: normal mode; logic 1: power-down mode) ST Self-test (logic 0: normal mode; logic 1: self-test) Leave unconnected NC Internally not connected Leave unconnected NC Internally not connected PLL filter connection pad #1 PLL filter connection pad #2 Vdd Power supply Vdd Power supply Vdd Power supply NC Internally not connected LISY300AL Function ...
Page 5
... LISY300AL 2 Mechanical and electrical specifications 2.1 Mechanical characteristics Table 3. Mechanical characteristics @ Vdd = 3 °C unless otherwise noted Symbol Parameter FS Measurement range So Sensitivity Sensitivity change vs. SoDr temperature (3) Voff Zero-rate level Zero-rate level change OffDr vs. temperature (4) NL Non linearity (3)(5) BW -3dB bandwidth Rn Rate noise density ...
Page 6
... The product is factory calibrated at 3 Typical specifications are not guaranteed 3. Referred to ANALOG OUTPUT pin #6 6/13 Test condition PD pin connected to GND PD pin connected to Vdd Logic 0 level Logic 1 level Logic 0 level Logic 1 level (3) Iout = ±100µA (3) LISY300AL (1) (2) Min. Typ. Max. 2.7 3.3 3.6 4 0.2*Vdd 0.8*Vdd ...
Page 7
... LISY300AL 2.3 Absolute maximum ratings Stresses above those listed as “Absolute maximum ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device under these conditions is not implied. Exposure to maximum rating conditions for extended periods may affect device reliability ...
Page 8
... ST is active, the device output level is given by the algebraic sum of the signals produced by the velocity acting on the sensor and by the electrostatic test-force. If the output signals change within the amplitude specified in properly and the parameters of the interface chip are within the defined specification. 8/13 Table 3, then the mechanical element is working LISY300AL ...
Page 9
... Power supply decoupling capacitors (100 nF ceramic or polyester + 10 µF Aluminum) should be placed as near as possible to the device (common design practice). The LISY300AL allows to band limit the output rate response through the use of two first- order on-chip filters: a switched capacitor low-pass filter, with 400Hz -3dB bandwidth, in combination with an active low-pass filter ...
Page 10
... Application hints The LISY300AL IC includes a PLL (phase locked loop) circuit to synchronize driving and sensing interfaces. Capacitors and resistors must be added at the FILTVDD and VCONT pads (as shown in summarizes the PLL low-pass filter components’ values. Table 6. PLL low-pass filter components’ values ...
Page 11
... LISY300AL 4 Package information In order to meet environmental requirements, ST offers these devices in ECOPACK® packages. These packages have a lead-free second level interconnect. The category of second level interconnect is marked on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. ECOPACK ® ...
Page 12
... Revision history 5 Revision history Table 7. Document revision history Date 29-May-08 12/13 Revision 1 Initial release LISY300AL Changes ...
Page 13
... LISY300AL Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. ...