T1610000 Red Lion Controls, T1610000 Datasheet - Page 13

Process/Temperature Controller

T1610000

Manufacturer Part Number
T1610000
Description
Process/Temperature Controller
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1610000

Operating Temperature Max
50°C
Operating Temperature Min
0°C
Output Voltage Max
250VAC
Controller Input
Thermocouple Or RTD
Supply Voltage Max
250VAC
Mounting Type
Panel Mount
Brand/series
T16 Series
Contact Form
SPST
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Thermocouple Type
J, K, T, E, R, S, B, N, C And Linear MV
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
arrow keys. To allow the P16 to “learn” the signal, use the Applied Method. For
Applied Method, press
applied method. Adjust the applied signal level externally until the appropriate
value appears under INP2. Using either method, press
INP2. (The controller can be toggled back to the Key-in Method by pressing
before
setting range of the setpoint. Set the limit so that the setpoint value cannot be
set below the safe operating area of the process.
setting range of the setpoint. Set the limit so that the setpoint value cannot be
set above the safe operating area of the process.
SELECTION
available only on models with alarms), when the User terminal 1 is connected
(pulled low) to Common terminal 8.
No Function: No function is performed.
Program Lock: The Configuration Loop is locked, as long as activated
Integral Action Lock: The integral action of the PID computation is disabled
Auto/Manual Select: This function selects (maintained action) Automatic
Setpoint 1 or 2 Select: This function selects (maintained action) Setpoint
Setpoint Ramp Disable: The setpoint ramping feature is disabled, as long as
Reset Alarms: Active alarms are reset, as long as activated (maintained action).
20. 0 0
999. 9
PLOC
NONE
PLOC
ILOC
trnF
INP2
For Key-in Method, enter the second coordinate Input Value by using the
SPLO
The controller has a programmable low setpoint limit value to restrict the
SPHI
The controller has a programmable high setpoint limit value to restrict the
InPt
The controller performs the selected User Input function (User Input
(maintained action).
(frozen), as long as activated (maintained action).
(open) or Manual Control (activated).
1(open) or Setpoint 2 (activated) as the active setpoint.
activated (maintained action). Any time the user input is activated with a
ramp in process, ramping is aborted.
Active alarms are reset until the alarm condition is cleared and triggered
again (momentary action).
.)
No Function
Program Lock
Integral Action Lock
Auto/Manual Select
0. 0 0
0. 0 0
-999
-999
FUNCTION
USER INPUT FUNCTION (OPTIONAL)
INPUT VALUE SCALING POINT 2
to
to
to
to
20. 0 0
10. 0 0
SETPOINT HIGH LIMIT
SETPOINT LOW LIMIT
. The ° annunciator is turned on to indicate the
9999
9999
SELECTION
mA
V
SPrP
ALrS
SPt
Setpoint 1 or 2 Select
Setpoint Ramp Disable
Reset Both Alarms
FUNCTION
to store the value for
13
SELECTION
while in the Display Loop. In any other loop or module location, pressing
will perform an escape to the Display Loop.
No Function: No function is performed.
Auto/Manual Select: This function toggles (momentary action) the controller
Setpoint 1 or 2 Selection: This function toggles (momentary action) the
Reset Alarms: This function can be used to reset one or both of the alarms
F1In
NONE
NONE
trnF
The controller performs the selected F1 key function, when
between Automatic and Manual Control.
controller between Setpoint 1 and Setpoint 2.
when activated (momentary action). The alarm will remain reset until the
alarm condition is cleared and triggered again.
SPt
No Function
Auto/Manual Select
Setpoint 1 or 2 Select
FUNCTION
F1 KEY FUNCTION
SELECTION
A1rS
A2rS
ALrS
Reset Alarm 1
Reset Alarm 2
Reset Both Alarms
FUNCTION
is pressed