T1610000 Red Lion Controls, T1610000 Datasheet - Page 17

Process/Temperature Controller

T1610000

Manufacturer Part Number
T1610000
Description
Process/Temperature Controller
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1610000

Operating Temperature Max
50°C
Operating Temperature Min
0°C
Output Voltage Max
250VAC
Controller Input
Thermocouple Or RTD
Supply Voltage Max
250VAC
Mounting Type
Panel Mount
Brand/series
T16 Series
Contact Form
SPST
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Thermocouple Type
J, K, T, E, R, S, B, N, C And Linear MV
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
explanation.
With reverse selection, the alarm annunciator indicates “off” alarm output.
Temperature/Process value leaves the alarm region. In Latched mode, an
energized alarm requires an F1 key or user input alarm reset to turn off. After an
alarm reset, the alarm remains reset off until the trigger point is crossed again.
setpoint change. After powering up the controller or changing the setpoint, the
process must leave the alarm region (enter normal non-alarm area of operation).
After this has occurred, the standby is disabled and the alarm responds normally
until the next controller power up or setpoint change.
entered in the Display or Hidden Loops. When the alarm is configured as
deviation or band acting, the associated output tracks the Setpoint as it is
changed. The value entered is the offset or difference from the Setpoint.
explanation.
AuHI
Auto
AuHI
ACt1
Select the action for the alarms. See Alarm Action Figures for a visual
With normal selection, the alarm annunciator indicates “on” alarm output 1.
rSt1
In Automatic mode, an energized alarm turns off automatically after the
Stb1
Standby prevents nuisance (typically low level) alarms after a power up or
AL-1
The alarm values are entered as process units or degrees. They can also be
ACt2
Select the action for the alarms. See Alarm Action Figures for a visual
nor
NO
0. 0
0
NONE
d-HI
NONE AbHI AbLO AuHI AuLO
d-HI d-LO b-IN b-ot CooL
T16
P16
nor
rEv
Auto
LAtc
YES
NO
ALARM ANNUNCIATOR ALARM 1
ALARM RESET MODE ALARM 1
ALARM STANDBY ALARM 1
ALARM ACTION ALARM 1
ALARM ACTION ALARM 2
ALARM VALUE ALARM 1
AbHI
d-LO
Normal
Reverse
Standby on
Standby off
Automatic
Latched
-999
AbLO
b-IN
to
9999
AuHI
b-ot
AuLO
HEAt
17
With reverse selection, the alarm annunciator indicates “off” alarm output.
Temperature/Process value leaves the alarm region. In Latched mode, an
energized alarm requires an F1 key or user input alarm reset to turn off. After an
alarm reset, the alarm remains reset off until the trigger point is crossed again.
setpoint change. After powering up the controller or changing the setpoint, the
process must leave the alarm region (enter normal non-alarm area of operation).
After this has occurred, the standby is disabled and the alarm responds normally
until the next controller power up or setpoint change.
entered in the Display or Hidden Loops. When the alarm is configured as
deviation or band acting, the associated output tracks the Setpoint as it is
changed. The value entered is the offset or difference from the Setpoint.
depending on the alarm action selected. The same value applies to both alarms.
See the Alarm Action Figures for a visual explanation of how alarm actions are
affected by the hysteresis.
Lit2
With normal selection, the alarm annunciator indicates “on” alarm output 2.
rSt2
Auto
In Automatic mode, an energized alarm turns off automatically after the
Stb2
Standby prevents nuisance (typically low level) alarms after a power up or
AL-2
The alarm values are entered as process units or degrees. They can also be
AHYS
The Hysteresis Value is either added to or subtracted from the alarm value,
nor
NO
2. 0
0. 1
20
1
T16
P16
T16
P16
nor
rEv
Auto
LAtc
YES
NO
ALARM ANNUNCIATOR ALARM 2
ALARM RESET MODE ALARM 2
ALARM STANDBY ALARM 2
ALARM VALUE ALARM 2
Normal
Reverse
Standby on
Standby off
ALARM HYSTERESIS
Automatic
Latched
-999
0
to
to
250
9999

Related parts for T1610000