T1620000 Red Lion Controls, T1620000 Datasheet - Page 15

Process/Temperature Controller

T1620000

Manufacturer Part Number
T1620000
Description
Process/Temperature Controller
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1620000

Operating Temperature Max
50°C
Operating Temperature Min
0°C
Temperature Accuracy ±
0.3%
Output Voltage Max
7V
Output Voltage Min
4V
Controller Input
Thermocouple Or RTD
Brand/series
T16 Series
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Mounting Type
Panel
Output Type
Digital/SSR
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Thermocouple Type
J, K, T, E, R, S, B, N, C And Linear MV
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
set to current. They must be changed if voltage output is desired. The Analog
output can be calibrated to provide up to approximately 5% over range
operation (0 mA current can only go slightly negative).
track.
actuator or pen recorder activity.
The following parameters can be configured for
7.3 MODULE 3 - L
dISP
HIdE
LOC
dSPr
SETPOINT
ACCESS
4-20
dISP
ANtP
Select the type of output and range. The Analog output jumpers are factory
ANAS
This setting selects the parameter that the Analog Output will retransmit or
ANUt
The update time of the Analog Output can be used to reduce excess valve
SELECTION
OP
SP
(SP only)
0
ANALOG OUTPUT ASSIGNMENT (OPTIONAL)
ANALOG OUTPUT RANGE (OPTIONAL)
0-10
4-20
0
0
InP
ANALOG UPDATE TIME (OPTIONAL)
OP
SP
= update rate of 0.1 second
to
Display: accessible in Display Loop.
Hide: accessible in Hidden Loop.
Locked: not accessible in either loop.
Display/read: read only in Display Loop,
but read/write in Hidden Loop.
ACCESS
OUTPUT
POWER
dISP
mA
Main Control % Output Power
Input Signal Retransmission
Active Setpoint
V
250
OP
0-20
seconds
DESCRIPTION
mA
PID VALUES
ACCESS
HIdE
PId
OCKOUT
LOC
,
HIdE
PARAMETER MENU
, and
ACCESS
VALUES
ALARM
HIdE
P
ARAMETERS
AL
dISP
.
15
output as selected.
output as selected. An inverse acting output can be achieved by reversing the
low and high scaling points.
The following parameters can be configured for
The Analog Output assignment value that corresponds to 0 V, 0 mA or 4 mA
ANHI
100. 0
The Analog Output assignment value that corresponds to 10 V or 20 mA
CodE
0. 0
0
SETPOINT
ACCESS
SELECT
SPSL
(
LOC
-1
ANALOG HIGH SCALING (OPTIONAL)
1
ANALOG LOW SCALING (OPTIONAL)
-125
to
to
0
-999
AUTO-TUNE
-125
125
ACCESS
START
HIdE
tUNE
to
to
)
Full access to Display, Hidden,
and Configuration Loops
Code necessary to access
Configuration Loop only.
Code necessary to access
Hidden and Configuration Loops.
to
ACCESS CODE
9999
SETPOINT
ACCESS
SPrP
HIdE
RAMP
ALARMS
ACCESS
RESET
ALrS
LOC
TRANSFER
CONTROL
ACCESS
LOC
trnF
LOC
or
HIdE
only
.

Related parts for T1620000