Automatically Set Data Links
Monitoring Data Link Status
Checking Automatically Set Data Link Tables
The following items can be monitored for a particular SYSMAC LINK Unit.
The Data Link Component Window is designed for manually setting data links. If data
link status is read from the Data Link Component while automatically set data links are
running, the data links may not be displayed properly. Furthermore, if the data link
tables that were read are then downloaded to a PLC, the data link tables that were
originally in the PLC will be overwritten. To prevent these problems, use the following
method to check automatically set data link tables.
1. Place the CX-Integrater online with the network PLC from which automatically set
2. Select Tools - Start Data Link from the menu bar to open the Data Link
3. Select Online - Datalink Operation/Status from the Data Link Component menu
4. The Datalink Status Dialog Box will be displayed.
Note: Supported for CVM1 and CV-series SYSMAC LINK Units only.
Note: Supported for CVM1 and CV-series SYSMAC LINK Units only.
data link tables are to be read.
Component.
bar.
Check the data link start node.
General
Error Information
Network Status
Data Link
Internode Test
(Parameters) (See
note.)
Internode Test
(Results) (See note.)
Tag name
Displays the words allocated in the CIO and DM Areas.
Data link errors, node setting errors, routing table errors,
communications controller errors, communications setting errors,
data verification errors, duplicate No. errors, parameter errors,
error logs, and EPROM write errors
Local node address, local network address, polling node local
address, unit number, power supply, internode test, and network
node address
Data link status (PLC operation status, PLC errors,
communications errors, data link participation status, offset errors,
and reception area insufficient space or surplus space)
Test beginning and end, test destination node address, test
destination network address, number of bytes sent, and response
monitor timer values
Test destination address, test destination network address,
number of bytes sent, response monitor timer values, number of
resend errors, number of non-responses, number of frame
overruns, number of tests, number of errors, number of token
timeouts, number of relay node routing failures, number of local
node routing failures, routing error MRES, routing error node
address, number of times local node failed to participate, number
of times data did not match, number of times test destination node
busy, routing error SRES, routing error network address, and test
status
Confirm the data
link start node here.