119152-52 AMETEK, 119152-52 Datasheet

BLOWER, 145MM, 240V, 1200W

119152-52

Manufacturer Part Number
119152-52
Description
BLOWER, 145MM, 240V, 1200W
Manufacturer
AMETEK
Series
Windjammerr
Type
Canisterr
Datasheets

Specifications of 119152-52

External Height
160.02mm
Current Type
AC
Supply Voltage
240VAC
Current Rating
5A
Flow Rate
90l/s
Power Connection Type
Pins
Depth
128.77mm
External Length / Height
160.02mm
Flow
RoHS Compliant
Air Flow
203 CFM
Brand/series
IntelliGen™
Configuration
Bypass
Controls
Mechanical
Current, Rating
10 A
Diameter, Inlet
1.75 "
Diameter, Outlet
1.75 "
Dimensions
145Dia x 130.3L mm
Power, Rating
1200 W
Special Features
Speed Control
Static Pressure
64 in.-H2O
Temperature, Operating, Maximum
+50 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
240 VAC
Weight
6 lbs.
Outer Diameter
145mm
Flow Rate - Imperial
190cu.ft/min
Flow Rate - Metric
522m3/h
Rohs Compliant
Yes
External Depth
128.77mm
Lead Free Status / Rohs Status
RoHS Compliant part
5.7” (145mm) DC Bypass Blower
Blower Data
Stages
Vacuum, Max. (Sealed Vacuum)
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
(Dimension “D” above)
Length (Dimension “I” above)
Length (Dimension “L” above)
Air Flow
0 CFM
20 CFM
40 CFM
60 CFM
80 CFM
100 CFM
120 CFM
140 CFM
160 CFM
180 CFM
200 CFM
220 CFM
240 CFM
260 CFM
280 CFM
300 CFM
*These part numbers are available through AMETEK Rotron distributors.
NOTES:
• Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
• Input current: 5 amps AC RMS maximum
• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C
• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
• Maximum Approximate Weight: 6 lbs.
Measure
Unit of
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
inches
inches
inches
mBar
mBar
L/sec
CFM
mm
mm
mm
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Standard Flow
117416 M*
117415 E*
174.50
53.85
144.3
129.1
102.9
31.75
60.8
10.8
1.25
2.12
6.87
135
335
144
357
82
39
3
Typical Performance Points
40
Pressure
119152 M*
119151 E*
128.77
11.94
44.45
5.11
54.0
53.9
51.1
47.0
43.2
37.0
29.4
22.3
14.2
124
134
190
1.75
.47
50
54
90
1
Part Number
High Flow
1200 WATT, 240 VOLT
119154 M*
119153 E*
161.29
38.86
44.45
1.53
97.0
92.5
85.8
75.9
62.3
40.5
32.1
15.0
1.75
6.35
226
241
156
91
97
74
2
Ultra Flow
69.85/63.50
119155 E*
2.75/2.50
138.94
17.78
39.2
38.0
37.5
35.3
33.5
31.4
28.0
25.4
21.5
18.5
16.1
13.1
10.0
5.47
307
145
.70
7.4
4.3
1.0
33
82
39
97
1

Related parts for 119152-52

119152-52 Summary of contents

Page 1

... Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C • Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. • Maximum Approximate Weight: 6 lbs. Part Number Standard Flow High Flow 117416 M* 119152 M* 117415 E* 119151 135 50 ...

Page 2

... Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications ...

Related keywords