KSZ8842-PMBL AM TR Micrel Inc, KSZ8842-PMBL AM TR Datasheet - Page 36

no-image

KSZ8842-PMBL AM TR

Manufacturer Part Number
KSZ8842-PMBL AM TR
Description
2-Port Ethernet Switch/Repeater + 32-bit/33MHz PCI Bus Interface( )
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8842-PMBL AM TR

Number Of Primary Switch Ports
2
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII
Power Supply Type
Analog/Digital
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.5V
Operating Supply Voltage (min)
3.1V
Operating Temperature Classification
Industrial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Supplier Unconfirmed
Micrel, Inc.
October 2007
23 – 20
14 – 11
10 – 0
Bit
25
24
19
18
17
16
15
Description
ES Error Summary
Indicates the logical OR of the following RDES0 bits:
CRC error
Frame too long
Runt frame
This bit is valid only when last descriptor is set.
MF Multicast Frame
When set, indicates that this frame has a multicast address.
This bit is valid only when last descriptor is set.
SPN Switch Engine Source Port Number
This field indicates the source port where the packet originated.
If bit 20 is set, it indicates the packet was received from port 1. If bit 21 is set, it indicates the
packet was received from port 2.
This field is valid only when the last descriptor is set.
(Bits 23 and 22 are not used, but reserved for backward compatibility and future expansion.)
RE Report on MII Error
When set, indicates that a receive error in the physical layer was reported during the frame
reception.
TL Frame Too Long
When set, indicates that the frame length exceeds the maximum size of 1518 bytes.
This bit is valid only when last descriptor is set.
Note: Frame too long is only a frame length indication and does not cause any frame
truncation.
RF Runt Frame
When set, indicates that this frame was damaged by a collision or premature termination
before the collision window has passed. Runt frames are passed on to the host only if the
pass bad frame bit is set.
CE CRC Error
When set, indicates that a CRC error occurred on the received frame.
This bit is valid only when last descriptor is set.
FT Frame Type
When set, indicates that the frame is an Ethernet-type frame (frame length field is greater
than 1500 bytes). When clear, indicates that the frame is an IEEE 802.3 frame.
This bit is not valid for runt frames.
This bit is valid only when last descriptor is set.
Reserved
FL Frame Length
Indicates the length, in bytes, of the received frame, including the CRC.
This field is valid only when last descriptor is set and descriptor error is reset.
36
KSZ8842-PMQL/PMBL
M9999-100207-1.5

Related parts for KSZ8842-PMBL AM TR