FLUKE-287/FVF Fluke Electronics, FLUKE-287/FVF Datasheet - Page 28

COMBO KIT DMM & ACCESSORY

FLUKE-287/FVF

Manufacturer Part Number
FLUKE-287/FVF
Description
COMBO KIT DMM & ACCESSORY
Manufacturer
Fluke Electronics
Series
FlukeView® Forms, 28xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-287/FVF

Includes
Battery, Case, Clips, Software, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Backlight, Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287/FVF
3340186
614-1151
287/289
Users Manual
the softkey labeled Save to store the MIN MAX screen data. MIN
MAX can not be continued at this point. Press the softkey labeled
Close to exit the MIN MAX mode.
Pressing the softkey labeled Restart while MIN MAX is running
stops the MIN MAX session, discards all MIN MAX data, and
immediately starts a new MIN MAX recording session.
Capturing Peak Values
Peak record is almost the same as MIN MAX record explained
earlier in this manual. The significant difference between the two
recording functions is the shorter response time for peak
recording: 250 s. With this short response time, the actual peak
values of a sinusoidal signal are measurable. Transients are
more accurately measured using the peak record feature.
To activate the peak mode, press the softkey labeled Menu.
Move the menu selector next to the menu item labeled Peak,CF
or Peak. Press the softkey labeled Peak to start the peak
recording session.
18
As shown in Figure 7, the primary display shows the “live”
measurement present on the Meter’s inputs. In the secondary
area of the display, the maximum and minimum peak values as
well as the average value are shown along with their respective
time stamps. The time stamp next to the average value indicates
the elapsed time of the peak recording session. The peak
recording session start time is shown along the bottom of the
page area of the display.
When the peak value of the input signal goes below the recorded
minimum value or above the recorded maximum value, the Meter
beeps and records the new value. At the same time, the elapsed
time since the peak recording session was started is stored as
the recorded value’s time stamp.
Peak Max
Average
Peak Min
Restart
8:10pm
119.8
Figure 7. Peak Record Display
-173.9
168.2
118.9
Start : 06/07/07 7:00 pm
V
VAC
V
Auto Range
VAC
00:03:17
01:10:59
01:10:09
06/07/07
500 VAC
Peak
Stop
est43.eps