8846A/SU 120V Fluke Electronics, 8846A/SU 120V Datasheet - Page 61

PREC MLTMTR 6.5DIGI USB W/SFTWRE

8846A/SU 120V

Manufacturer Part Number
8846A/SU 120V
Description
PREC MLTMTR 6.5DIGI USB W/SFTWRE
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheets

Specifications of 8846A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
6.5
Display Type
VFD, Dual
Display Count
Varies
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Memory, RS-232, USB Port
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2675344
614-1003
2. Press the STORE READINGS soft key shown above.
3. If not already highlighted, press the INTERNAL MEMORY soft key.
4. Press the #SAMPLES soft key.
5. To adjust the number of samples, press either <-- or --> to select a digit.
6. With the desired number of samples set, press the ENTER soft key to return to the
7. Press the START soft key to initiate measurement storing. The START soft key
To store readings in external memory (8846A Only)
1. Press M.
2. Press the STORE READINGS soft key.
3. Press the USB soft key.
4. Press the #SAMPLES soft key.
5. To adjust the number of samples, press either <-- or --> to select a digit.
6. With the number of samples set, press the ENTER soft key to return to the Store
7. Press the START soft key to begin storing measurements. The START soft key will
For internal storage of readings, the number of readings stored will not
exceed 9999 readings regardless of the value set for number of samples.
With the desired digit selected, press the soft key labeled -- to decrement the digit
or ++ to increment the character. When 2
secondary reading is counted as a sample and appears in a separate line/row in the
readings file.
store readings menu.
will change to STOP which can be pressed to stop the storage process. When the
requested number of samples have been stored, the soft key label changes back to
START. The MEM annunciator in the display also illuminates while readings are
being stored.
With the chosen digit selected, press the soft key labeled -- to decrement the digit
or ++ to increment the character.
Readings menu.
change to STOP which can be pressed to stop the storage process. When the
requested number of samples have been stored, the soft key label changes back to
START. The MEM annunciator in the display also illuminates while readings are
being stored.
F1
+
0.5993
F2
F3
Note
nd
Meas is enabled, each primary and
F4
F5
Controlling Trigger Functions
Front-Panel Operation
caw032.eps
3-19