28014 Parallax Inc, 28014 Datasheet - Page 39

OSCILLOSCOPE USB 200KHZ

28014

Manufacturer Part Number
28014
Description
OSCILLOSCOPE USB 200KHZ
Manufacturer
Parallax Inc
Type
USBr
Datasheets

Specifications of 28014

Includes
Probes, Software, USB Cable
Bandwidth
200kHz
Channels
Dual
Display Type
None - Requires Computer and Monitor
Probe Type
Hook Probes x1 (3)
Sampling Rate (per Second)
500ks/s
Voltage - Input, Max
20V p-p
Voltage - Supply
5 VDC, USB Powered
Product
Microcontroller Accessories
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Input Impedance
-
Rise Time (typ)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q2119020
ACTIVITY #2: MEASURING TIME-VARYING SERVO PULSES
Use the same parts and circuitry as the previous activity. No changes to the OPTAscope
settings are required.
Time-Varying Pulse Widths with the ServoSweep.bs2 Program
' Understanding Signals - ServoSweep.bs2
' Demonstrate a changing servo pulse
' {$STAMP BS2}
' {$PBASIC 2.5}
PulseWidth
Counter
Run the program ServoSweep.bs2, which will vary the pulse width.
Press the Run / Stop button when the pulse is at its widest.
Measure the pulse width using the Vertical Bars cursor setting.
Repeat this process to measure the pulse at its narrowest extreme.
Are your measurements different? Calibrate! If your measurements vary from those in
the text, you may try calibrating your OPTAscope to see if that is the source of the
discrepancy. To begin, disconnect all probes from your circuit. Then select Calibrate from
the File drop-down menu on the OPTAscope task bar, and follow the directions.
VAR
VAR
Word
Word
' Pulse length
' Pulse counter
Figure 2-9:
The delta
symbol ∆
shows a pulse
width of 1.500
ms.