28014 Parallax Inc, 28014 Datasheet - Page 97

OSCILLOSCOPE USB 200KHZ

28014

Manufacturer Part Number
28014
Description
OSCILLOSCOPE USB 200KHZ
Manufacturer
Parallax Inc
Type
USBr
Datasheets

Specifications of 28014

Includes
Probes, Software, USB Cable
Bandwidth
200kHz
Channels
Dual
Display Type
None - Requires Computer and Monitor
Probe Type
Hook Probes x1 (3)
Sampling Rate (per Second)
500ks/s
Voltage - Input, Max
20V p-p
Voltage - Supply
5 VDC, USB Powered
Product
Microcontroller Accessories
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Input Impedance
-
Rise Time (typ)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q2119020
Using the External Trigger with 38kHzInfraredwithVaryingFrequency.bs2
' Understanding Signals - 38kHzInfraredwithVaryingFrequency.bs2
' 38 kHz infrared signal with detector feedback
' {$STAMP BS2}
' {$PBASIC 2.5}
DO
LOOP
HIGH 0
FREQOUT 7,3,38500
FREQOUT 7,1,38500
FREQOUT 7,1,38500
FREQOUT 7,2,38500
FREQOUT 7,2,38500
FREQOUT 7,1,38500
FREQOUT 7,1,38500
FREQOUT 7,2,38500
FREQOUT 7,1,38500
LOW 0
PAUSE 20
Configure your OPTAscope with the following settings. Note: to set the external
trigger at 10%, press the T button at the top left corner of the Plot Area, click the
right T button to move it back.
Point the IR LED and IR detector towards each other.
Connect the External Trigger TTL probe to P0 using a jumper wire.
Run the program 38kHzInfraredwithVaryingFrequency.bs2.
CH1
CH2
Horizontal Dial
Trigger Source
Trigger Edge
Trigger Mode
Run / Stop Mode
Trigger Voltage
Autoscale
1 V / division
2 V / division
1 ms / division
External at 10%
N/A
Normal
Continuous
N/A
On
Figure 7-8:
OPTAscope
configuration for
capturing infrared
signals