Characteristics
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. Contact your OMRON sales representative
*3. These figures are minimum requirements for safe operation.
Degree of protection *1
Durability *2
Operating speed
Operating frequency
Direct opening force *3
Direct opening travel *3
Contact resistance
Rated insulation voltage (U
Rated frequency
Protection against electric shock
Pollution degree (operating environment)
Impulse withstand
voltage
(EN60947-5-1)
Insulation resistance
Contact gap
Vibration
resistance
Shock resistance
Conditional short-circuit current
Conventional enclosed thermal current (I
Ambient operating temperature
Ambient operating humidity
Weight
the operating conditions and environment beforehand. Although the switch box is protected from dust, oil, or water penetration, do not use the
D4BS in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning
may occur.
for more detailed information on other operating environments.
Mechanical
Electrical
Between terminals of
same polarity
Between terminals of
different polarity
Between each
terminal and ground
Malfunction
Destruction
Malfunction
i
)
the
) 20 A (EN60947-5-1)
IP67 (EN60947-5-1)
1,000,000 operations min.
500,000 operations min. (10 A resistive load at 250 VAC)
0.1 m/s to 0.5 m/s
30 operations/minute max.
19.61 N min. (EN60947-5-1)
20 mm min. (EN60947-5-1)
25 mΩ max.
600 V (EN60947-5-1)
50/60 Hz
Class I (with ground terminal)
3 (EN60947-5-1)
4 kV
100 MΩ min. (at 500 VDC) between terminals of same or different polarity, between each
terminal and ground, and between each terminal and non-current-carrying metal part
2 × 2 mm min.
10 to 500 Hz, 0.65 mm single amplitude
1,000 m/s
300 m/s
100 A (EN60947-5-1)
−40 to 80°C (with no icing)
95% max.
Approx. 285 g (D4BS-15FS)
2
min. (IEC68-2-27)
2
min. (IEC68-2-27)
D4BS
3