D4BS-65FS Omron, D4BS-65FS Datasheet - Page 5

no-image

D4BS-65FS

Manufacturer Part Number
D4BS-65FS
Description
SAFETY LIMIT SWITCH
Manufacturer
Omron
Datasheet
Dimensions and Operating Characteristics
Switches
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* The conduit thread varies with the model as follows:
1-conduit
D4BS-1@@S
D4BS-2@@S
D4BS-3@@S
3-conduit
D4BS-5@@S
D4BS-6@@S
D4BS-7@@S
D4BS-1@@S, D4BS-5@@S: Pg 13.5
D4BS-2@@S, D4BS-6@@S: G1/2
D4BS-3@@S, D4BS-7@@S: 1/2-14NPT
2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application.
Red
Red
(110)
(111.5)
66.4
60±0.2
50.9
35
8
5.3
28.5
30±0.1
40
31.4
5.3
17
30±0.2
31.4
+1
0
17
51
57
63
Two, 5.3 dia.
mounting holes
Two, M4 cover
clamping screws
Six, 5.3 dia.
mounting holes
Four, M3.5 x 10 cover
clamping screws
7.3
7
Two caps
7
Cover
Cover
*
15
43
41
31.5
38.3
35.7
41
17.2
16
16
Four, M3.5 head
clamping screws
*
34.5
Two, 5
holes (6 mm deep)
Four, M3.5 head
clamping screws
77
71.4
34.5
75.4
+0.15
−0
dia.
Operating
characteristics
Operating
characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Total travel
Direct opening force
Direct opening stroke
Key insertion force
Key extraction force
Pretravel (PT)
Total travel
Direct opening force
Direct opening stroke
Model
Model
D4BS-1@@S
D4BS-2@@S
D4BS-3@@S
D4BS-5@@S
D4BS-6@@S
D4BS-7@@S
19.61 N max.
19.61 N max.
19.61 N max.
19.61 N max.
23 mm min.
19.61 N min.
20 mm min.
23 mm min.
19.61 N min.
20 mm min.
(Unit: mm)
10±5 mm
10±5 mm
D4BS
5