CS1W-CRM21 Omron, CS1W-CRM21 Datasheet - Page 335

no-image

CS1W-CRM21

Manufacturer Part Number
CS1W-CRM21
Description
CS1 CompoNet Master
Manufacturer
Omron
Datasheet

Specifications of CS1W-CRM21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
The check box for each applicable status will be selected.
Unit Status
Master Function
Status
Communication
Cycle Time
Name
Communication
Mode
Baud Rate
Communications
Error
Communications
Stop Mode
Registration
Table
Network Power
Voltage OFF
Remote I/O
Communication
Running
Communications
Error
Node Address
Duplication Error
Structure Error
Comparison Error
(Non-Existent
Slave)
Comparison Error
(Unregistered
Slave)
Remote I/O
Communications
Suspended
Because of
Communications
Error
Software Setting
Table Logical
Error
Slave
Registration
Logical Error
Slave Parameter
Logical Error
Network
Parameter
Logical Error
Present Value
• The mode is set the Software Setting Mode (Mode 8)
• The Software Table is corrupted.
• The Registration Table is disabled, but the Registration
Displays the number of the communications
mode set on the rotary switch on the front of
the Master Unit.
Displays the baud rate set on DIP switch
pins SW1 and SW2 on the front of the
Master Unit when the Unit power was
turned ON.
Displays the setting of DIP switch pin SW3
(ESTP) when the power was turned ON.
When this pin is ON, a communications
error on any slave will cause all remote I/O
communications to stop.
Displays the setting of DIP switch pin SW4
(REGS) on the front of the Master Unit
when the power was turned ON.
When this pin is ON, only Slave Units that
are registered will be able to participate in
the network. At the same time, if the node
address of the active Slave Unit does not
match the node address of a Slave Unit
registered in the Registration Table, a
comparison error will occur.
Displays the status of the network power
supply.
Remote I/O communications are running.
The slave has left the network.
The address of a Slave Unit attempting to participate in the
network is the same as the address of another Slave Unit.
The
participation on the network have exceeded the maximum
allowable number of Repeater layers (2 layers).
A Slave Unit was detected that is registered in the
Registration Table but did not join the network within the
fixed time period from the time that the Unit power was
turned ON.
The monitoring time is set using the CX-Integrator
Software.
An unregistered slave was detected joining the network.
A communications error was detected while
communications were set to be stopped when a
communications error occurred.
• The Registration Table is corrupted.
The Slave Unit Parameter Table is corrupted.
The Network Parameters Table is corrupted.
Displays the present value of the communications cycle
time in milliseconds.
even though the Software Table is disabled.
Table Enable Setting (REGS) is turned ON (enabled).
Slave
7-4-2 Master Unit Monitor Window
Units
Description
and
7-4 Component Monitor
Repeater
Units
0,1,2,3,8
4 Mbps,
3 Mbps,
1.5 Mbps,
93.75 kbps
Enabled,
disabled
Enabled,
disabled
-
requesting
Value
7-11