LAN8720A-CP-TR SMSC, LAN8720A-CP-TR Datasheet - Page 56

no-image

LAN8720A-CP-TR

Manufacturer Part Number
LAN8720A-CP-TR
Description
Ethernet ICs RMII 10/100 ETH XCVR w/HP AutoMDIXSupport
Manufacturer
SMSC
Datasheet

Specifications of LAN8720A-CP-TR

Product
Ethernet Transceivers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN8720A-CP-TR
Manufacturer:
MORNSUN
Quantity:
1 000
Part Number:
LAN8720A-CP-TR
Manufacturer:
SMSC
Quantity:
20 000
Part Number:
LAN8720A-CP-TR
0
Part Number:
LAN8720A-CP-TR-ABC
0
Revision 1.2 (11-10-10)
4.2.8
15:14
12:10
BITS
8:7
5:2
13
9
6
1
0
RESERVED
EDPWRDOWN
Enable the Energy Detect Power-Down mode:
0 = Energy Detect Power-Down is disabled
1 = Energy Detect Power-Down is enabled
RESERVED
FARLOOPBACK
Enables far loopback mode (i.e., all the received packets are sent back
simultaneously (in 100BASE-TX only)). This mode works even if the Isolate
bit (0.10) is set.
0 = Far loopback mode is disabled
1 = Far loopback mode is enabled
Refer to
information.
RESERVED
ALTINT
Alternate Interrupt Mode:
0 = Primary interrupt system enabled (Default)
1 = Alternate interrupt system enabled
Refer to
information.
RESERVED
ENERGYON
Indicates whether energy is detected. This bit transitions to “0” if no valid
energy is detected within 256ms. It is reset to “1” by a hardware reset and
is unaffected by a software reset. Refer to
Power-Down," on page 38
RESERVED
Mode Control/Status Register
Section 3.8.8.2, "Far Loopback," on page 40
Section 3.6, "Interrupt Management," on page 29
Index (In Decimal): 17
for additional information.
DESCRIPTION
DATASHEET
Section 3.8.3.2, "Energy Detect
56
Size:
Small Footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support
for additional
for additional
16 bits
SMSC LAN8720A/LAN8720Ai
TYPE
R/W
R/W
R/W
R/W
RO
RO
RO
RO
RO
DEFAULT
Datasheet
0b
0b
0b
1b
0b
-
-
-
-