Specifications of FLUKE-287 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
50 MV To 50 V
Voltage Measuring Range Ac
500 V To 1000 V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
287/289
Users Manual
Measuring AC and DC Signals
The Meter is capable of displaying both ac and dc signal
components (voltage or current) as two separate readings or one
AC+DC (rms) value combined. As shown in Figure 13, the Meter
displays ac and dc combinations three ways: ac displayed over
dc (AC,DC), dc displayed over ac (DC,AC), and ac combined
with dc (AC+DC). Select one of these three displays using the
Function and Mode menu.
With the rotary switch set to U, N, A, or X, press the
softkey labeled Menu. Move the menu selector to the menu item
labeled AC+DC. At this point, three different softkey labels
Both manual and autoranging is available when using the ac+dc
modes. The same range is used for both ac and dc signals.
26
Menu
8:10pm
123.45
Save
AC over DC
23.45
06/13/07
VAC
Auto Range
VDC
Setup
500 VAC
Menu
Figure 13. AC and DC Display
8:10pm
23.45
DC over AC
Save
123.45
indicate AC+DC (F1), AC,DC (F2), and DC,AC (F3). Press the
softkey that presents these two signals as needed.
While in any of the three AC+DC modes, peak measurements,
frequency, duty cycle, and period measurements are not
allowed. In addition to these modes, MIN MAX, relative, and
relative % are not allowed in AC,DC or DC,AC modes.
However, while in autorange, up-ranging occurs when either the
ac or dc signal exceeds the present range. Down-ranging occurs
06/13/07
VDC
Auto Range
The bar graph is not displayed while the Meter is in
any of the three AC+DC modes.
VAC
Setup
500 V
Menu
8:10pm
125.66
Note
Save
AC + DC
23.45
06/13/07
V
AC + DC
Auto Range
VDC
Setup
500 V
est30.eps