FLUKE-287 CALIBRATED Fluke, FLUKE-287 CALIBRATED Datasheet - Page 66

MULTIMETER, DIGITAL, HANDHELD

FLUKE-287 CALIBRATED

Manufacturer Part Number
FLUKE-287 CALIBRATED
Description
MULTIMETER, DIGITAL, HANDHELD
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-287 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
50 MV To 50 V
Voltage Measuring Range Ac
500 V To 1000 V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
287/289
Users Manual
Error Messages
Table 10 list some of the error messages the Meter may display and the conditions that may be causing the error.
56
Leads connected incorrectly.
Open Thermocouple
Batteries low – function
unavailable.
Error: Date and Time need to be
reset.
Not enough memory for
operation.
Batteries critically low, replace
now.
Message
Lead in A or mA/ A jack but
position
Leads in both A and mA/ A jacks.
Rotary switch set to measure current but no lead in either A or mA/ A jack.
Thermocouple wire is open or thermocouple junction is corroded.
No Thermocouple connected to the Meter’s input.
The function selected requires a higher battery level to operate within specifications.
Batteries were left out too long and the Meter’s date and time were lost.
When starting a recording session or saving screen data, the Meter does not have
enough memory to store the information.
Battery is too low to make measurements within stated specifications. The Meter will turn
off within 15 seconds after this message appears to preserve the Meter’s date and time.
.
Table 10. Error Messages
rotary switch not in corresponding A/mA or A
Conditions