Specifications of FLUKE-287 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
50 MV To 50 V
Voltage Measuring Range Ac
500 V To 1000 V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
True-rms Digital Multimeters
Making Measurements
To change whether the beeper sounds on shorts or opens, press
the softkey labeled Menu. Move the menu selector to the menu
item labeled Beeper and press the softkey labeled Short/O….
This beeper selection, Beep on Short or Beep on Open, is
displayed just above the continuity indicator. The continuity
beeper is always enabled when continuity mode if first entered.
To enable or disable the beeper for continuity, press the softkey
labeled Menu. Move the menu selector to the menu item labeled
Beeper and press the softkey labeled Beeper. The status of the
continuity beeper is displayed to the right of the resistance
reading with j when enabled and i when disabled. This setting
is independent of the Meter’s beeper enable/disable setting in
the setup menu.
Toggle between the continuity and ohms functions by pressing
softkey F3, which is always labeled with the alternate function.