N2735A OPTION 004 AGILENT TECHNOLOGIES, N2735A OPTION 004 Datasheet - Page 24

no-image

N2735A OPTION 004

Manufacturer Part Number
N2735A OPTION 004
Description
Oscilloscope Software
Manufacturer
AGILENT TECHNOLOGIES
Series
DSO7000r
Datasheet

Specifications of N2735A OPTION 004

No. Of Channels
4
Scope Bandwidth
350 MHz
Scope Type
Hand Held
Lead Free Status / RoHS Status
na
Performance characteristics
General characteristics (continued)
Trigger out
10 MHz ref in/out
Kensington lock
Power requirements
Line voltage range
Line frequency
Power usage
Environmental characteristics
Ambient temperature
Humidity
Altitude
Vibration
Shock
Pollution degree
Typical operator noise
Indoor use
Other
Measurement categories
Regulatory information
Supplementary information
24
When Triggers is selected (delay ~17 ns)
When Source Frequency or Source Frequency/8 is selected
Max frequency output: 350 MHz (in source frequency mode when terminated in 50 Ω)
TTL out, 180 mV to 1 V amplitude with 0 to 2 V offset
Connection on rear panel for security
100-120V, 50/60/400 Hz; 100-240V, 50/60 Hz auto ranging
50/60 Hz, 100-240 VAC; 400 Hz, 100-120 VAC
120 W max
Operating -10 °C to +55 °C; non-operating –40 °C to +70 °C
Operating: Up to 95% relative humidity (non-condensing) at +40 °C
Non-operating: Up to 90% relative humidity at +65 °C
Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft)
Agilent class B1 and MIL-PRF-28800F; class 3 random
Agilent class B1 and MIL-PRF-28800F; class 3 random; (operating 30g, 1/2 sine,
11 ms duration, 3 shocks/axis along major axis, total of 18 shocks)
Normally only dry non-conductive pollution occurs.
Occasionally a temporary conductivity caused by condensation must be expected.
30 dBa at front of instrument, 35 dBa at rear of instrument.
Rated for indoor use only
CAT I
Safety IEC 61010-1:2001 / EN 61010-1:2001
Canada: CSA C22.2 No. 1010.1:1992
UL 61010B-1:2003
The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly.
The product was tested in a typical configuration with HP/Agilent test systems.
0 to 5 V into high impedance
0 to 2.5 V into 50 Ω
0 to 580 mV into high impedance
0 to 290 mV into 50 Ω
(continued)
125 MHz (in source frequency/8 mode when terminated in 50 Ω)