SC16C654DBIB64 NXP Semiconductors, SC16C654DBIB64 Datasheet - Page 32

IC, UART, QUAD, 64BYTE FIFO, 16C654

SC16C654DBIB64

Manufacturer Part Number
SC16C654DBIB64
Description
IC, UART, QUAD, 64BYTE FIFO, 16C654
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C654DBIB64

Data Rate
5Mbps
Transmit Fifo
64Byte
Receive Fifo
64Byte
Transmitter And Receiver Fifo Counter
Yes
Package Type
LQFP
Operating Supply Voltage (max)
5.5V
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
No. Of Channels
4
Supply Voltage Range
2.25V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
64
Svhc
No SVHC (18-Jun-2010)
Uart Features
Programmable Xon/Xoff Characters, Software Selectable Baud Rate Generator
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C654DBIB64,128
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C654DBIB64,151
Manufacturer:
NXP
Quantity:
144
Part Number:
SC16C654DBIB64,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C654DBIB64,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C654DBIB64151
Manufacturer:
NXP Semiconductors
Quantity:
135
Philips Semiconductors
9397 750 14965
Product data sheet
Table 19:
Bit
4
3
2
1
0
Symbol
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
Modem Control Register bits description
Description
Loop-back. Enable the local loop-back mode (diagnostics). In this mode the
transmitter output (TX) and the receiver input (RX), CTS, DSR, CD, and RI are
disconnected from the SC16C654B/654DB I/O pins. Internally the modem
data and control pins are connected into a loop-back data configuration; see
Figure
operational. The Modem Control Interrupts are also operational, but the
interrupts’ sources are switched to the lower four bits of the Modem Control.
Interrupts continue to be controlled by the IER register.
OP2, INTx enable. Used to control the modem CD signal in the loop-back
mode.
OP1. This bit is used in the Loop-back mode only. In the loop-back mode, this
bit is used to write the state of the modem RI interface signal via OP1.
RTS
Automatic RTS may be used for hardware flow control by enabling EFR[6].
See
DTR
5 V, 3.3 V and 2.5 V quad UART, 5 Mbit/s (max.) with 64-byte FIFOs
logic 0 = disable loop-back mode (normal default condition)
logic 1 = enable local loop-back mode (diagnostics)
logic 0 = forces INTA-INTD outputs to the 3-state mode during the 16 mode
(normal default condition). In the loop-back mode, sets OP2 (CD) internally
to a logic 1.
logic 1 = forces the INTA-INTD outputs to the active mode during the
16 mode. In the loop-back mode, sets OP2 (CD) internally to a logic 0.
logic 0 = force RTS output to a logic 1 (normal default condition)
logic 1 = force RTS output to a logic 0
logic 0 = force DTR output to a logic 1 (normal default condition)
logic 1 = force DTR output to a logic 0
Table
Rev. 02 — 20 June 2005
12. In this mode, the receiver and transmitter interrupts remain fully
22.
SC16C654B/654DB
…continued
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
32 of 58

Related parts for SC16C654DBIB64