BZE6-7RNT Honeywell, BZE6-7RNT Datasheet - Page 2

Basic / Snap Action / Limit Switches Top Plunger Actuator 14 NPT conduit

BZE6-7RNT

Manufacturer Part Number
BZE6-7RNT
Description
Basic / Snap Action / Limit Switches Top Plunger Actuator 14 NPT conduit
Manufacturer
Honeywell
Type
Basicr
Datasheets

Specifications of BZE6-7RNT

Pole Throw Configuration
SPDT
Switch Function Configuration
N.O./N.C.
Current Rating (max)
15A
Terminal Type
Screw
Contact Form
SPDT - 1 NC / 1 NO
Contact Rating
15 Amps
Actuator
Plunger
Operating Force
7.78 N to 15.01 N
Termination Style
Screw
Ingress Protection
IP66 / NEMA 1, 3, 4
Actuator Type
Plunger
Brand/series
E6 Series
Current, Rating
0.5 A
Ip Rating
IP54
Material, Contact
Zinc Die-Cast (Housing)
Mounting Type
Side Mount
Number Of Poles
1
Number Of Positions
2
Standards
UL Recognized, CSA Certified, NEMA Approved
Temperature, Operating
-32 to +71 °C
Termination
Screw
Lead Free Status / RoHS Status
Compliant
Basic Switches
Subminiature/Miniature
ELECTRICAL DATA AND UL CODES
MINIATURE/SUBMINIATURE BASIC SWITCHES
Most of the switches in this section are UL recognized and CSA
certified. The current and voltage values shown are based on
test conditions specified by these agencies. Electrical life of the
switch is influenced by each application condition as well as by
voltage and current.
20
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Honeywell Sensing and Control
Circuitry
M UL rating:
A 5 amps res., 3 amps ind., (sea level),
B 7 amps res., 4 amps ind., (sea level),
C 3.5 amps res., 2 amps ind., (sea level),
D 1 amp res., 0.5 amp ind., (sea level
G 2 amps res., lamp ind., (sea level)
H .010 amp res. and ind., (sea level).
K UL rating:
N 1 amp res., 0.5 amp ind., 30 vdc.
R 5 amps res., 3 amps ind., 2.4 amps
E 3 amps res., 2 amps ind., (sea level),
F 7 amps res., 4 amps ind., 2.5 amps
J 5 amps res., 3 amps ind., (sea level),
L 1 amp res., 1/2 amp ind.,
P 1 amp res., 30 vdc.
I 7 amps res., 4 amps ind., (sea level),
4 amps res., 2 amps ind., (50,000
feet), 28 vdc
5 amps res. or ind. 115 vac, 60 Hz.
UL/CSA rating: 5 amps, 250 vac.
7 amps res., 2.5 amps ind., (50,000
feet), 28 vdc.
UL/CSA rating: 7 amps, 250 vac.
3.5 amps res., 1.5 amps ind., (50,000
feet), 28 vdc.
UL rating: 7 amps, 250 vac.
and 50,000 feet), 28 vdc.
UL/CSA rating: 1 amp, 125 vac.
28 vdc.
UL rating: 3 amps, 250 vac.
lamp load, (sea level),
4 amps res., 2.5 amps ind., 2.5 amps
lamp load, (50,000 feet), 28 vdc.
7 amps res., 7 amps ind., 2 amps lamp
load, 115 vac, 60 Hz (sea level).
28 vdc.
28 vdc.
UL/CSA rating: 1 amp, 125 vac.
28 vdc.
5 amps res., 2.5 amps ind.,
(50,000 feet), 28 vdc.
UL rating: 5 amps, 250 vac.
5 amps, 125 or 250 vac.
(sea level) 28 vdc.
11 amps and 1/4 hp, 125 or 250 vac.
UL rating: 1 amp, 125 vac.
UL rating: .1 amp, 125 vac.
lamp load (sea level),
5 amps res., 2.5 amps ind., 2.4 amps
lamp load, (50,000 feet), 28 vdc.
5 amps res., 5 amps ind., 1.5 amps
lamp load, 115 vac. 60 Hz (sea level)
Electrical Data
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
unless
otherwise
noted in
order guide
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
Two-circuit
double-break
Four-circuit
double-break
Single-pole
double-throw
Single-pole
double-throw
Single-pole
double-throw
For application help: call 1-800-537-6945.
Circuitry
UU 10 amps res., 10 amps ind., (sea
AA UL rating:
BB UL rating:
TT UL/CSA rating:
VV UL/CSA rating:
YY UL/CSA rating:
ZZ UL rating:
W 10 amps, 250 vac or 28 vdc;
U UL/CSA rating:
S UL rating:
T UL/CSA rating:
V UL/CSA rating:
X UL rating:
Y 10 amps and 1/3 hp, 125 or 250 vac;
Z 10 amps, 125 or 250 vac, or 30 vdc.
4 amps, 250 vac.
11 amps and 1/3 hp, 125, 250, or 277
vac;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
4 amps, 125 vac ‘‘L’’ (lamp load).
10 amps and 1/3 hp, 125 or 250 vac;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
4 amps, 125 vac ‘‘L’’ (lamp load).
level),
6 amps ind. (50,000 feet), 6 amps
motor load, 30 vdc.
15.1 amps and 1/2 hp, 125 or 250 vac.
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
5 amps, 120 vac ‘‘L’’ (lamp load).
3 amps-125, 250, 277 vac;
1/10 hp-250 vac
10 amps and 1/4 hp, 125 or 250 vac;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
3 amps, 125 vac ‘‘L’’ (lamp load).
1/2 amp, 125 vdc; 1/4 amp, 250 vdc.
1 amp, 125 vac.
4 amps, 125 vac ‘‘L’’ (lamp load).
5 amps-125, 250, 277 vac
1/10 hp-250 vac
UL/CSA rating:
10 amps, 125 or 250 vac; 1/2 hp, 125
vac.
5 amps and 1/10 hp.
125 or 250 vac.
20 amps, 277 vac.
1 hp, 125 vac; 2 hp, 250 vac.
25 amps, 277 vac.
1 hp, 125 vac; 2 hp, 250 vac.
Electrical Data

Related parts for BZE6-7RNT