BZE6-7RNT Honeywell, BZE6-7RNT Datasheet - Page 75

Basic / Snap Action / Limit Switches Top Plunger Actuator 14 NPT conduit

BZE6-7RNT

Manufacturer Part Number
BZE6-7RNT
Description
Basic / Snap Action / Limit Switches Top Plunger Actuator 14 NPT conduit
Manufacturer
Honeywell
Type
Basicr
Datasheets

Specifications of BZE6-7RNT

Pole Throw Configuration
SPDT
Switch Function Configuration
N.O./N.C.
Current Rating (max)
15A
Terminal Type
Screw
Contact Form
SPDT - 1 NC / 1 NO
Contact Rating
15 Amps
Actuator
Plunger
Operating Force
7.78 N to 15.01 N
Termination Style
Screw
Ingress Protection
IP66 / NEMA 1, 3, 4
Actuator Type
Plunger
Brand/series
E6 Series
Current, Rating
0.5 A
Ip Rating
IP54
Material, Contact
Zinc Die-Cast (Housing)
Mounting Type
Side Mount
Number Of Poles
1
Number Of Positions
2
Standards
UL Recognized, CSA Certified, NEMA Approved
Temperature, Operating
-32 to +71 °C
Termination
Screw
Lead Free Status / RoHS Status
Compliant
Basic Switches
Standard
PIN PLUNGER
56
Unoperated
Honeywell Sensing and Control
Dim. Dwg. Fig. 4-A
Dim. Dwg. Fig. 6
Dim. Dwg. Fig 5
Intermediate
ORDER GUIDE
BZ-2G-A2
6BS1-B
10BS210
Catalog Listing
GENERAL INFORMATION
SPECIAL CIRCUITRY SWITCHES
‘‘Special sequence’’ switches provide un-
usual circuit control. A make-before-
break switch provides circuit continuity
while switching from N.C. to N.O. In an-
other make-before-make switch, upon
actuation, one circuit is made an interval
before the second circuit. Another switch
Adjustable
differential travel
Recommended For
Make-before-break
contact action
Make-before-make
contact action
Operated
Fully
20 Amps
Electrical
UL Codes
Data and
Page 46
10 Amps
10 Amps
Y
Intermediate
C
R
Release
For application help: call 1-800-537-6945.
3,10-5,56
11-20
newtons
20 max.
35 max.
ounces
5,56
O.F.
9,73
R.F. min. P.T. max. O.T. min.
newtons
ounces
2,78
10
Characteristics: O.F. – Operating Force;
R.F. – Release Force; P .T. – Pretravel;
O.T. – Overtravel; D.T. – Differential Travel;
O.P . – Operating Position.
2,22
2,78
10
8
provides a single pulse or momentary
closure of the contacts with each cycle of
operation.
Double break versions can interrupt grea-
ter inductive loads and feature shorting
bar construction. A split contact version
allows control of the two isolated circuits.
Released
inches
.030
0,76
mm
Fully
setting
.010 at
max.
0,25
inches
.005
0,13
mm
.007 at max.
BZ/BA Series
.0015-.0025
0,04-0,06
setting
inches
0,18
.015
0,38
D.T.
mm
* 0,38 mm
inches
O.P .*
15,9
.625
mm
16,3
.015 in.
.64

Related parts for BZE6-7RNT