BZE6-7RNT Honeywell, BZE6-7RNT Datasheet - Page 40

Basic / Snap Action / Limit Switches Top Plunger Actuator 14 NPT conduit

BZE6-7RNT

Manufacturer Part Number
BZE6-7RNT
Description
Basic / Snap Action / Limit Switches Top Plunger Actuator 14 NPT conduit
Manufacturer
Honeywell
Type
Basicr
Datasheets

Specifications of BZE6-7RNT

Pole Throw Configuration
SPDT
Switch Function Configuration
N.O./N.C.
Current Rating (max)
15A
Terminal Type
Screw
Contact Form
SPDT - 1 NC / 1 NO
Contact Rating
15 Amps
Actuator
Plunger
Operating Force
7.78 N to 15.01 N
Termination Style
Screw
Ingress Protection
IP66 / NEMA 1, 3, 4
Actuator Type
Plunger
Brand/series
E6 Series
Current, Rating
0.5 A
Ip Rating
IP54
Material, Contact
Zinc Die-Cast (Housing)
Mounting Type
Side Mount
Number Of Poles
1
Number Of Positions
2
Standards
UL Recognized, CSA Certified, NEMA Approved
Temperature, Operating
-32 to +71 °C
Termination
Screw
Lead Free Status / RoHS Status
Compliant
Position Sensors
Miniature Hermetically Sealed Switches
HM ORDER GUIDE
HM MOUNTING
A force spreading plate is recommended to reduce the
chance of product damage due to excessive mounting force.
MOUNTING PLATE
Torque on #2 mounting screws must be restricted to 1.5 inch
pounds max. to prevent switch damage. The force spreading
mounting plate used as shown will allow up to 2.5 inch
pounds of mounting torque.
Honeywell Sensing and Control 1-800-537-6945 USA
NOTICE
Fig. 1
Fig. 2
Fig. 3
Fig. 4
11HM1
(MS27216-5)
13HM1
9HM1
(MS27216-6)
2HM19-1
(MS27216-2)
2HM19-5
(MS27216-4)
16HM1-1
15HM2
Catalog
Listing
19PA137-HM
Most applications.
Exceeds MIL-S-8805
requirements for
shock and vibration.
Applications requiring
gold contacts
Bifurcated gold
contacts
MIL-S-8805
application
requirements 1 ft.
(305mm) leads
5 foot (1524mm) long
leads
High temperature to
500 F (260 C) flat
spring
Operating in
temperatures to
weld tab termination.
Recommended For
500 F (260 C) with
Electrical
Rating
Code
1-815-235-6847 International 1-416-293-8111 Canada
H
K
J
L
L
I
I
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P . — Operating Position.
O.F. max.
Newtons
ounces
1,95
1,95
1,95
1,95
1,95
1,95
1,95
7
7
7
7
7
7
7
Newtons
R.F. min.
ounces
0,28
0,28
0,28
0,28
0,28
0,28
0,28
1
1
1
1
1
1
1
Operating Characteristics
P .T. max.
inches
0,76
.030
0,76
.030
0,76
.030
0,76
.030
0,76
.030
0,76
.030
0,76
.030
mm
O.T. min.
inches
0,08
.003
0,08
.003
0,08
.003
0,08
.003
0,08
.003
0,08
.003
0,08
.003
mm
D.T. max.
inches
.006
.006
.006
.006
.006
.006
.006
0,15
0,15
0,15
0,15
0,15
0,15
0,15
mm
19
HM Series
.015 (0,38 mm)
inches
.330
.330
.330
.330
.330
.330
.330
8,38
8,38
8,38
8,38
8,38
8,38
8,38
O.P .
mm

Related parts for BZE6-7RNT