CAT5409YI-50-T2 ON Semiconductor, CAT5409YI-50-T2 Datasheet - Page 10

no-image

CAT5409YI-50-T2

Manufacturer Part Number
CAT5409YI-50-T2
Description
IC POT DPP QUAD 64TAP I2C 24TSSO
Manufacturer
ON Semiconductor
Datasheet

Specifications of CAT5409YI-50-T2

Taps
64
Resistance (ohms)
50K
Number Of Circuits
4
Temperature Coefficient
300 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.5 V ~ 6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Resistance In Ohms
50K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Wiper Control and Data Registers
Wiper Control Register (WCR)
Registers, one for each potentiometer. The Wiper Control
Register output is decoded to select one of 64 switches along
its resistor array. The contents of the WCR can be altered in
four ways: it may be written by the host via Write Wiper
Control Register instruction; it may be written by
transferring the contents of one of four associated Data
Registers via the XFR Data Register instruction, it can be
modified one step at a time by the Increment/decrement
instruction (see Instruction section for more details).
Finally, it is loaded with the content of its data register zero
(DR0) upon power−up.
its contents when the CAT5409 is powered−down. Although
the register is automatically loaded with the value in DR0
upon power−up, this may be different from the value present
at power−down.
Table 12. INSTRUCTION SET
Read Wiper
Control Register
Write Wiper Control
Register
Read Data
Register
Write Data Register
XFR Data Register
to Wiper Control
Register
XFR Wiper Control
Register to Data
Register
Gang XFR Data
Registers to Wiper
Control Registers
Gang XFR Wiper
Control Registers
to Data Register
Increment/
Decrement Wiper
Control Register
The CAT5409 contains four 6−bit Wiper Control
The Wiper Control Register is a volatile register that loses
Instruction
I3
1
1
1
1
1
1
0
1
0
I2
0
0
0
1
1
1
0
0
0
(Note: 1/0 = data is one or zero)
I1
0
1
1
0
0
1
0
0
1
I0
1
0
1
0
1
0
1
0
0
Instruction Set
1/0
1/0
1/0
1/0
1/0
1/0
R1
0
0
0
http://onsemi.com
R0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
0
WCR1/ P1
10
1/0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
Data Registers (DR)
Registers. These can be read or written directly by the host.
Data can also be transferred between any of the four Data
Registers and the associated Wiper Control Register. Any
data changes in one of the Data Registers is a non−volatile
operation and will take a maximum of 5 ms.
settings for the potentiometer, the Data Registers can be used
as standard memory locations for system parameters or user
preference data.
Instructions
These instructions are:
Each potentiometer has four 6−bit non−volatile Data
If the application does not require storage of multiple
Four of the nine instructions are three bytes in length.
Read Wiper Control Register – read the current wiper
position of the selected potentiometer in the WCR
Write Wiper Control Register – change current wiper
position in the WCR of the selected potentiometer
Read Data Register – read the contents of the selected
Data Register
Write Data Register – write a new value to the
selected Data Register
WCR0/ P0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
Read the contents of the Wiper Control
Register pointed to by P1−P0
Write new value to the Wiper Control
Register pointed to by P1−P0
Read the contents of the Data Register
pointed to by P1−P0 and R1−R0
Write new value to the Data Register
pointed to by P1−P0 and R1−R0
Transfer the contents of the Data
Register pointed to by P1−P0 and
R1−R0 to its associated Wiper Control
Register
Transfer the contents of the Wiper
Control Register pointed to by P1−P0 to
the Data Register pointed to by R1−R0
Transfer the contents of the Data
Registers pointed to by R1−R0 of all four
pots to their respective Wiper Control
Registers
Transfer the contents of both Wiper
Control Registers to their respective data
Registers pointed to by R1−R0 of all four
pots
Enable Increment/decrement of the
Control Latch pointed to by P1−P0
Operation

Related parts for CAT5409YI-50-T2