ADBM-A350-200 Avago Technologies US Inc., ADBM-A350-200 Datasheet - Page 52

no-image

ADBM-A350-200

Manufacturer Part Number
ADBM-A350-200
Description
Vigor Colossus OFN Module
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ADBM-A350-200

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SC_T_DOUBLE
Access: Read/Write
Data Type: Bit fi eld
USAGE: This register is used to set time between fi rst click and second click to trigger double click. Any second succes-
SC_DELTA_THRESH
Access: Read/Write
Data Type: Bit fi eld
USAGE: This register is used to set sensor single click threshold.
SC_STATUS
Access: Read/Write
Data Type: Bit fi eld
USAGE: This register is used to confi rm which soft click has been triggered when there is a soft click interrupt being
52
Bit
Field
Bit
Field
Bit
Field
sive click within this time will be considered a double click.
triggered.
Field Name
SC_Dou 7:0
Field Name
SC_Delta 7:0
Field Name
Tap_N_Hold
Double_Click
Single_Click
7
SC_Dou
7
SC_Delta
7
Reserved
6
SC_Dou
6
SC_Delta
6
Reserved
Description
Sets waiting time after single click for double click to happen
Description
Threshold to validate single click. Single click is only valid if motion delta sum
(Delta_X + Delta_Y) is less than threshold. Units are in 500 cpi.
Description
0 = Tap and Hold not detected
1 = Tap and Hold detected
0 = Double click not detected
1 = Double click detected
0 = Single click not detected
1 = Single click detected
Address: 0x7d
Reset Value: 0x1e
Address: 0x7e
Reset Value: 0x19
Address: 0x7f
Reset Value: 0x00
5
SC_Dou
5
SC_Delta
5
Reserved
4
SC_Dou
4
SC_Delta
4
Reserved
3
SC_Dou
3
SC_Delta
3
Reserved
2
SC_Dou
2
SC_Delta
2
Tap+N_
Hold
1
SC_Dou
1
SC_Delta
1
Double_
Click
0
SC_Dou
0
SC_Delta
0
Single_
Click