SPAKDSP303AG100 Freescale Semiconductor, SPAKDSP303AG100 Datasheet - Page 18

no-image

SPAKDSP303AG100

Manufacturer Part Number
SPAKDSP303AG100
Description
IC DSP 24BIT 100MHZ 144-LQFP
Manufacturer
Freescale Semiconductor
Series
DSP563xxr
Type
Fixed Pointr
Datasheets

Specifications of SPAKDSP303AG100

Interface
Host Interface, SSI, SCI
Clock Rate
100MHz
Non-volatile Memory
ROM (576 B)
On-chip Ram
24kB
Voltage - I/o
3.30V
Voltage - Core
3.30V
Operating Temperature
-40°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
144-LQFP
Device Core Size
24b
Clock Freq (max)
100MHz
Mips
100
Device Input Clock Speed
100MHz
Ram Size
24KB
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
144
Package Type
LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPAKDSP303AG100
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Signals/Connections
1.10 Serial Communication Interface (SCI)
The SCI provides a full duplex port for serial communication with other DSPs, microprocessors, or peripherals
such as modems.
1-14
RXD
PE0
TXD
PE1
SCLK
PE2
Notes:
Signal Name
1.
2.
3.
In the Stop state, the signal maintains the last state as follows:
• If the last state is input, the signal is an ignored input.
• If the last state is output, the signal is tri-stated.
The Wait processing state does not affect the signal state.
All inputs are 5 V tolerant.
Input
Input or Output
Output
Input or Output
Input/Output
Input or Output
Type
Table 1-14.
State During
Ignored Input
Ignored Input
Ignored Input
Reset
DSP56303 Technical Data, Rev. 11
1,2
Serial Communication Interface
Serial Receive Data—Receives byte-oriented serial data and transfers it to the
SCI Receive Shift Register.
Port E 0—The default configuration following reset is GPIO input PE0. When
configured as PE0, signal direction is controlled through the Port E Direction
Register. The signal can be configured as an SCI signal RXD through the Port E
Control Register.
Serial Transmit Data—Transmits data from the SCI Transmit Data Register.
Port E 1—The default configuration following reset is GPIO input PE1. When
configured as PE1, signal direction is controlled through the Port E Direction
Register. The signal can be configured as an SCI signal TXD through the Port E
Control Register.
Serial Clock—Provides the input or output clock used by the transmitter and/or
the receiver.
Port E 2—The default configuration following reset is GPIO input PE2. When
configured as PE2, signal direction is controlled through the Port E Direction
Register. The signal can be configured as an SCI signal SCLK through the Port
E Control Register.
Signal Description
Freescale Semiconductor