EP2C5T144C8N Altera, EP2C5T144C8N Datasheet - Page 152

IC CYCLONE II FPGA 5K 144-TQFP

EP2C5T144C8N

Manufacturer Part Number
EP2C5T144C8N
Description
IC CYCLONE II FPGA 5K 144-TQFP
Manufacturer
Altera
Series
Cyclone® IIr
Datasheet

Specifications of EP2C5T144C8N

Number Of Logic Elements/cells
4608
Number Of Labs/clbs
288
Total Ram Bits
119808
Number Of I /o
89
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
144-TQFP, 144-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-1665

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2C5T144C8N
Manufacturer:
ALTERA
Quantity:
28
Part Number:
EP2C5T144C8N
Manufacturer:
ALTERA73
Quantity:
6 170
Part Number:
EP2C5T144C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C5T144C8N
Manufacturer:
ALTERA
0
Part Number:
EP2C5T144C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2C5T144C8N
0
Part Number:
EP2C5T144C8N@@@@@
Manufacturer:
ALTERA
0
Part Number:
EP2C5T144C8NK
Manufacturer:
ALTERA
0
Timing Specifications
5–62
Cyclone II Device Handbook, Volume 1
Notes to
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10) For extended temperature devices, the maximum output jitter (peak to peak) is 600 ps.
(11) For extended temperature devices, the maximum t
(12) For extended temperature devices, the maximum lock time is 500 us.
t
t
F A L L
L O C K
Table 5–50. LVDS Transmitter Timing Specification (Part 2 of 2)
Symbol
The maximum data rate that complies with duty cycle distortion of 45–55%.
The maximum data rate when taking duty cycle in absolute ps into consideration that may not comply with 45–55%
duty cycle distortion. If the downstream receiver can handle duty cycle distortion beyond the 45–55% range, you
may use the higher data rate values from this column. You can calculate the duty cycle distortion as a percentage
using the absolute ps value. For example, for a data rate of 640 Mbps (UI = 1562.5 ps) and a t
duty cycle distortion is ± t
distortion of 42–58%.
The TCCS specification applies to the entire bank of LVDS, as long as the SERDES logic is placed within the LAB
adjacent to the output pins.
For extended temperature devices, the maximum input clock frequency for ×10 through ×2 modes is 137.5 MHz.
For extended temperature devices, the maximum data rate for ×10 through ×2 modes is 275 Mbps.
For extended temperature devices, the maximum input clock frequency for ×10 through ×2 modes is 200 MHz.
For extended temperature devices, the maximum data rate for ×10 through ×2 modes is 400 Mbps.
For extended temperature devices, the maximum input clock frequency for ×1 mode is 340 MHz.
For extended temperature devices, the maximum data rate for ×1 mode is 340 Mbps.
Table
Conditions
80–20%
5–50:
Min
150
–6 Speed Grade
D U T Y
Typ
200
/(UI*2) *100% = ± 250 ps/(1562.5 *2) * 100% = ± 8%, which gives you a duty cycle
Max
(1)
250
100
Max
(2)
Min
150
R I S E
–7 Speed Grade
and t
Typ
200
FA L L
Max
(1)
are 300 ps.
250
100
Max
(2)
Min
150
–8 Speed Grade
Typ
200
Altera Corporation
D U T Y
Max
(1)
250
100
February 2008
of 250 ps, the
(11)
(12)
Max
(2)
Unit
ps
μs