PMR8210P Ericsson Power Modules, PMR8210P Datasheet - Page 3

DC/DC Switching Controllers PoL Regul in 4.5-14V O/P 0.7-3.6 50A

PMR8210P

Manufacturer Part Number
PMR8210P
Description
DC/DC Switching Controllers PoL Regul in 4.5-14V O/P 0.7-3.6 50A
Manufacturer
Ericsson Power Modules
Datasheet

Specifications of PMR8210P

Number Of Outputs
1
Output Voltage
3 V to 5.25 V
Output Current
40 A
Output Power
132 W
Switching Frequency
600 KHz
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E
Prepared (also subject responsible if other)
ESLUOAN
Approved
SEC/D (Julia You)
PMR 8000 series PoL Regulator
Input 8 - 14 V, Output up to 40 A / 210 W
On-board DC-DC converters and DC/DC regulators are
defined as component power supplies. As components
they cannot fully comply with the provisions of any Safety
requirements without “Conditions of Acceptability”.
Clearance between conductors and between conductive
parts of the component power supply and conductors on
the board in the final product must meet the applicable
Safety requirements. Certain conditions of acceptability
apply for component power supplies with limited stand-off
(see Mechanical Information for further information). It is
the responsibility of the installer to ensure that the final
product housing these components complies with the
requirements of all applicable Safety standards and
Directives for the final product.
Component power supplies for general use should comply
with the requirements in IEC60950, EN60950 and UL60950
“Safety of information technology equipment”.
There are other more product related standards, e.g.
IEEE802.3af “Ethernet LAN/MAN Data terminal equipment
power”, and ETS300132-2 “Power supply interface at the
input to telecommunications equipment; part 2: DC”, but all
of these standards are based on IEC/EN/UL60950 with
regards to safety.
Ericsson Power Modules DC/DC converters and DC/DC
regulators are UL60950 recognized and certified in
accordance with EN60950.
The flammability rating for all construction parts of the
products meets requirements for V-0 class material
according to IEC 60695-11-10.
The products should be installed in the end-use equipment,
in accordance with the requirements of the ultimate
application. Normally the output of the DC/DC converter is
considered as SELV (Safety Extra Low Voltage) and the
input source must be isolated by minimum Double or
Reinforced Insulation from the primary circuit (AC mains) in
accordance with IEC/EN/UL60950.
Isolated DC/DC converters
It is recommended that a slow blow fuse with a rating twice
the maximum input current per selected product be used at
the input of each DC/DC converter. If an input filter is used
in the circuit the fuse should be placed in front of the input
filter.
In the rare event of a component problem in the input filter
or in the DC/DC converter that imposes a short circuit on
the input source, this fuse will provide the following
functions:
Isolate the faulty DC/DC converter from the input
power source so as not to affect the operation of
other parts of the system.
Protect the distribution wiring from excessive
current and power loss thus preventing hazardous
overheating.
Checked
Ericsson Internal
PRODUCT SPECIFICATION
No.
1/1301-BMR 629 8210 Uen
Date
2009-8-21
The galvanic isolation is verified in an electric strength test.
The test voltage (V
1500 Vdc or 2250 Vdc for 60 seconds (refer to product
specification).
Leakage current is less than 1 µA at nominal input voltage.
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
48 and 60 V DC systems
If the input voltage to the DC/DC converter is 75 Vdc or
less, then the output remains SELV (Safety Extra Low
Voltage) under normal and abnormal operating conditions.
Single fault testing in the input power supply circuit should
be performed with the DC/DC converter connected to
demonstrate that the input voltage does not exceed
75 Vdc.
If the input power source circuit is a DC power system, the
source may be treated as a TNV2 circuit and testing has
demonstrated compliance with SELV limits and isolation
requirements equivalent to Basic Insulation in accordance
with IEC/EN/UL60950.
Non-isolated DC/DC regulators
The input voltage to the DC/DC regulator is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
Technical Specification
EN/LZT 146 411 R1B November 2009
© Ericsson AB
A
Rev
iso
) between input and output is
Reference
A
3 (4)
3

Related parts for PMR8210P