PMR8210P Ericsson Power Modules, PMR8210P Datasheet - Page 6

DC/DC Switching Controllers PoL Regul in 4.5-14V O/P 0.7-3.6 50A

PMR8210P

Manufacturer Part Number
PMR8210P
Description
DC/DC Switching Controllers PoL Regul in 4.5-14V O/P 0.7-3.6 50A
Manufacturer
Ericsson Power Modules
Datasheet

Specifications of PMR8210P

Number Of Outputs
1
Output Voltage
3 V to 5.25 V
Output Current
40 A
Output Power
132 W
Switching Frequency
600 KHz
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3.3V, 40A /132W Typical Characteristics
Efficiency
Output Current Derating
Output Ripple & Noise
Output voltage ripple at:
T
I
O
P1
E
= 40 A resistive load.
[%]
100
[A]
50
40
30
20
10
Prepared (also subject responsible if other)
ECOCOLO
Approved
PMR 8000 series PoL Regulator
Input 8 - 14 V, Output up to 40 A / 210 W
= +25°C, V
95
90
85
80
75
0
Efficiency vs. load current and input voltage at T
Available load current vs. ambient air temperature and airflow at
V
0
I
0
= 12 V. See Thermal Consideration section.
I
5
20
= 12 V,
10
40
15
60
20
25
80
Trace: output voltage (5 mV/div.).
Time scale: (2 µs/div.).
30
100
35
120 [°C]
P1
40 [A]
= +25°C
Checked
EJANLLI
2.0 m/s
1.0 m/s
0.5 m/s
Nat.
Conv.
8.0 V
12.0 V
14.0 V
Power Dissipation
Output Characteristics
Output Voltage Adjust (see operating information)
Passive adjust
The resistor value for an adjusted output voltage is calculated by using the
equations in the operating information.
R
[V]
3.45
3.40
3.35
3.30
3.25
[W]
1 0
8
6
4
2
0
SET
Ericsson Internal
PRODUCT SPECIFICATION
No.
2/1301-BMR 629 8210 Uen
Date
2009-08-31
0
0
=
Dissipated power vs. load current and input voltage at
T
O
V
P1
utput voltage vs. load current at T
O
30
= +25°C
5
1 .
0
0
7 .
7 .
5
1 0
0
10
7 .
. 8
10
1 5
25
( )
Technical Specification
EN/LZT 146 411 R1B November 2009
© Ericsson AB
Rev
B
k
Ω
20
15
25
P1
20
Reference
= +25°C
30
35
25
40 [A ]
30 [A]
PMR 8210
8.0 V
1 2.0 V
1 4.0 V
8.0 V
12.0 V
14.0 V
3 (6)