PMR8210P Ericsson Power Modules, PMR8210P Datasheet - Page 8

DC/DC Switching Controllers PoL Regul in 4.5-14V O/P 0.7-3.6 50A

PMR8210P

Manufacturer Part Number
PMR8210P
Description
DC/DC Switching Controllers PoL Regul in 4.5-14V O/P 0.7-3.6 50A
Manufacturer
Ericsson Power Modules
Datasheet

Specifications of PMR8210P

Number Of Outputs
1
Output Voltage
3 V to 5.25 V
Output Current
40 A
Output Power
132 W
Switching Frequency
600 KHz
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E
5V, 40A /200W Typical Characteristics
Efficiency
Output Current Derating
Output Ripple & Noise
Output voltage ripple at:
T
I
O
Prepared (also subject responsible if other)
ECOCOLO
Approved
PMR 8000 series PoL Regulator
Input 8 - 14 V, Output up to 40 A / 210 W
P1
= 40 A resistive load.
[%]
100
[A]
50
40
30
20
10
= +25°C, V
95
90
85
80
75
0
Efficiency vs. load current and input voltage at T
Available load current vs. ambient air temperature and airflow at
V
0
0
I
= 12 V. See Thermal Consideration section.
I
5
20
= 12 V,
10
40
15
60
20
25
80
30
Trace: output voltage (5 mV/div.).
Time scale: (2 µs/div.).
100
35
40 [A]
120 [°C]
P1
= +25°C
Checked
EJANLLI
8.0
12.0 V
14.0 V
2.0 m/s
1.0 m/s
0.5 m/s
Nat.
Conv.
Ericsson Internal
PRODUCT SPECIFICATION
No.
2/1301-BMR 629 8210 Uen
Date
2009-08-31
Power Dissipation
Output Characteristics
Output Voltage Adjust (see operating information)
Passive adjust
The resistor value for an adjusted output voltage is calculated by
using the equations in the operating information.
R
[W]
10
[V]
5.15
5.10
5.05
5.00
4.95
SET
8
6
4
2
0
0
Dissipated power vs. load current and input voltage at
T
0
O
=
P1
utput voltage vs. load current at T
V
O
= +25°C
30
5
1 .
0
0
5
7 .
7 .
10
0
10
7 .
Technical Specification
EN/LZT 146 411 R1B November 2009
© Ericsson AB
Rev
B
10
15
. 8
25
( )
k
15
20
Ω
25
Reference
20
P1
30
= +25°C
25
35
30 [A]
40 [A]
PMR 8210
8.0 V
12.0 V
14.0 V
8.0 V
12.0 V
14.0 V
5 (6)
8

Related parts for PMR8210P