IC TXRX E1 1CHIP 5V ENH 100-LQFP

DS2154L+

Manufacturer Part Number
DS2154L+
Description
IC TXRX E1 1CHIP 5V ENH 100-LQFP
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of DS2154L+

Number Of Drivers/receivers
1/1
Protocol
E1
Voltage - Supply
4.75 V ~ 5.25 V
Mounting Type
Surface Mount
Package / Case
100-LQFP
Product
Framer
Number Of Transceivers
1
Data Rate
1.544 Mbps
Supply Voltage (max)
5.25 V
Supply Voltage (min)
4.75 V
Supply Current (max)
75 mA (Typ)
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Ic Interface Type
Parallel, Serial
Supply Voltage Range
4.75V To 5.25V
Operating Temperature Range
0°C To +70°C
Digital Ic Case Style
LQFP
No. Of Pins
100
Filter Terminals
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SR2: STATUS REGISTER 2 (Address = 07 Hex)
(MSB)
RMF
SYMBOL
RCMF
LOTC
TSLIP
RMF
TMF
RAF
SEC
TAF
RAF
POSITION
SR2.7
SR2.5
SR2.4
SR2.3
SR2.1
SR2.0
SR2.6
SR2.2
TMF
NAME AND DESCRIPTION
Receive CAS Multiframe. Set every 2ms (regardless if CAS
signaling is enabled or not) on receive multiframe boundaries.
Used to alert the host that signaling data is available.
Receive Align Frame. Set every 250µs at the beginning of align
frames. Used to alert the host that Si and Sa bits are available in
the RAF and RNAF registers.
Transmit Multiframe. Set every 2ms (regardless if CRC4 is
enabled) on transmit multiframe boundaries. Used to alert the
host that signaling data needs to be updated.
1-Second Timer. Set on increments of 1 second based on
RCLK. If CCR2.7 = 1, then this bit will be set every 62.5 ms
instead of once a second.
Transmit Align Frame. Set every 250µs at the beginning of
align frames. Used to alert the host that the TAF and TNAF
registers need to be updated.
Loss of Transmit Clock. Set when the TCLK pin has not
transitioned for one channel time (or 3.9µs). Will force the
LOTC pin high if enabled via TCR2.0.
Receive CRC4 Multiframe. Set on CRC4 multiframe
boundaries; will continue to be set every 2ms on an arbitrary
boundary if CRC4 is disabled.
Transmit Elastic Store Slip. Set when the elastic store has
either repeated or deleted a frame of data.
SEC
36 of 87
TAF
LOTC
RCMF
TSLIP
(LSB)