ISE30A-N01-P-L SMC Corporation, ISE30A-N01-P-L Datasheet

no-image

ISE30A-N01-P-L

Manufacturer Part Number
ISE30A-N01-P-L
Description
Sensor, High-Precision Digital Pressure (positive), 1-PNP Open Collector Output
Manufacturer
SMC Corporation
Datasheet

Specifications of ISE30A-N01-P-L

Display
4-Digit, 7 Segment, 2-Color LCD (red/green)
Function
High Precision, Digital Positive Pressure Sensor
Ip Rating
IP 40
Mounting Type
Panel or Bracket
Output
1 - PNP Open Collector
Primary Type
Pressure
Range, Measurement
-0.100 to 1.000 MPa
Sensing Mode
Air, Non-Corrosive Gas, Non-Flammable Gas
Termination
Lead Wire, Oilproof Heavy Duty Vinyl Cable
Voltage, Supply
12 to 24 VDC
2-Color Display
High-Precision Digital Pressure Switch
Series
RoHS
Settings can be
Settings can be
Settings can be
The settings of the master sensor can be copied to the slave sensors.
b
3 3
3
2 added outputs
b
b
Reduced setting efforts
0
0
NPN or PNP open collector 2 outputs
NPN or PNP open collector 1 output + Analog output
(1 to 5 V or 4 to 20 mA)
-step setting
-step setting
-step setting
–101 kPa
–0.1 MPa
(–100 kPa)
1 MPa
Push
Push
Push
Master
compliant
1
ZSE30A
Added vacuum range.
b
Expanded pressure range
for positive-pressure type
to the vacuum range.
b
Rated pressure range: 0.0 to –101.0 kPa
Rated pressure range: –0.100 to 1.000 MPa
Adjust to set-value
with
Slave →
2
copied
copied
copied
buttons.
Unit 1
(
b
F
Reduced chance of set-value input error
Finish setting
)
to up to
to up to
to up to
/ISE30A
Push
Push
Push
3
Unit 2
10 10
10
slave sensors at once.
slave sensors at once.
slave sensors at once.
CAT.ES100-70A
Unit 10

Related parts for ISE30A-N01-P-L

ISE30A-N01-P-L Summary of contents

Page 1

... NPN or PNP open collector 2 outputs b NPN or PNP open collector 1 output + Analog output ( mA) RoHS compliant ZSE30A Series Reduced chance of set-value input error Unit 1 Unit 2 3 Push Push Push Finish setting buttons /ISE30A slave sensors at once. slave sensors at once. slave sensors at once. Unit 10 CAT.ES100-70A ...

Page 2

... Mounting example 4-digit display 4-digit display allows easy reading of displayed values. Example: 0.5 MPa Possible to check set-value during key locking Additional functions ISE30A (compound) (positive) v Secret code setting function The key locking function keeps unauthorized persons from tampering with buttons. v Power-saving function Power consumption is reduced by turning off the monitor ...

Page 3

... ISE30A F∗ PNP open collector 1 output + Analog current output –0 MPa ∗ Made to Order Piping Straight type Elbow type Option 1 Note) Connector cover Note /ISE30A Option 3 Operating manual Calibration Symbol certificate Booklet CD-ROM Nil — — Y — — — W — — ...

Page 4

... Mounting screw (with 2 pcs 8L) ZS-38-N7H ZS-38-C4L 3 cores, for 1 output cores, for 2 outputs ZS-38-C6L 3 cores, for 1 output ZS-38-N7L 4 cores, for 2 outputs ZS-38-H ISE30A (Compound pressure) (Positive pressure) –100.0 to 100.0 kPa –0.100 to 1.000 MPa –105.0 to 105.0 kPa –0.105 to 1.050 MPa 500 kPa 1.5 MPa 0.1 kPa ...

Page 5

... Can convert the display value. Reduces power consumption. Converts display resolution from the normal value of 1/1000 to 1/100. It reduces the monitor to flicker. Converts the unit between kPa and MPa ZSE30A F /ISE30A A B Rated pressure range 0.0 to –101.0 kPa — 0 –100.0 to 100.0 kPa — ...

Page 6

... Black OUT1 White OUT2 FUNC Blue DC (–) Max Residual voltage less ∗ The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used. (Refer to “Copy function” on page 10 /ISE30A P PNP (1 output) Load + VDC – Max Residual voltage less ...

Page 7

... VDC – Max Residual voltage less Analog current output Max. load impedance: Power supply voltage 12 V: 300 Ω Power supply voltage 24 V: 600 Ω Min. load impedance: 50 Ω /ISE30A Brown DC (+) Black OUT1 + White OUT2 VDC – Load FUNC Load Blue DC (–) ...

Page 8

... C4H One-touch fitting ø4 mm ø5/32 inch straight 17.55 10.85 C4L One-touch fitting ø4 mm ø5/32 inch elbow 20.7 ø9.3 10. /ISE30A 25 8 9.5 Lead wire with connector 01: R1/8 N01: NPT1/8 1.5 C6H One-touch fitting ø6 mm straight 17.95 10.85 C6L One-touch fitting ø6 mm elbow 22 ...

Page 9

... High-Precision Digital Pressure Switch With bracket ( ) Z/ISE30A F A1 Bracket A (Option unit part no.: ZS-38-A1) A2 Bracket B (Option unit part no.: ZS-38-A2) 2-Color Display ZSE30A Series Option 7.5 7 /ISE30A 42.5 25 34.6 ∗ Bracket configuration allows mounting in four orientations. ∗ Bracket configuration allows mounting in four orientations. 1.6 25 16.4 7 ...

Page 10

... ZSE30A F Series Dimensions Panel mount ( ) Z/ISE30A F B Panel mount adapter (Option unit part no.: ZS-27-C) 34.5 D Panel mount adapter + Front protection cover (Option unit part no.: ZS-27-D) 42.4 33 /ISE30A Option 2 9.5 7.2 17.8 8 8.5 Panel thickness 0 17.8 8 9.5 Panel thickness 0 47.8 ...

Page 11

... High-Precision Digital Pressure Switch Panel-cut dimensions 1 pc. mounting 0 31 –0.4 2-Color Display ZSE30A Series Multiple (2 pcs. or more) horizontal mounting pcs pcs. – 1) Multiple (2 pcs. or more) vertical mounting more –0 /ISE30A 9 ...

Page 12

... Adjustable range of display calibration function Note) When the precision indicator setting function is used, the set pressure value may change ±1 digit /ISE30A Unit 10 1) The sensors are connected by a dedicated lead wire (ZS-38-5L (for master and one slave) or ZS-38-U (for Slave master and slaves)) ...

Page 13

... It can be set whether code number input is required or not when key is locked set to input no code number when ex-factory ZSE30A F /ISE30A Solution Shut off the power supply. After eliminating the out- put factor that caused the excess current, turn the power supply back on. Bring the pressure back to atmospheric pressure and try using the zero-out function ...

Page 14

... Do not use in an environment where static electri- city can cause problems, otherwise system failure or malfunction may result. Back page /ISE30A Mounting Caution 1. Mounting and removing with panel mount adapter Panel Panel mount adapter To release push the claws ...

Page 15

... ZSE30AF pound –105 kPa pressure For –100 kPa positive ISE30A –105 kPa pressure (–0.105 MPa /ISE30A Pressure range 0 100 kPa 500 kPa 0 10 kPa 100 kPa 105 kPa 1 MPa 1 MPa 1.05 MPa Rated pressure range of switch Set pressure range of switch Back page 4 ...

Related keywords