Start Code and End Code
Number of Received Bytes
RS-232C Port Settings for PLC Link (PC Link (Slave))
Serial Communications Mode
Baud Rate
PLC Link Unit No. (PC Link Unit Number)
318
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
+164
+165
+165
+160
+161
+167
Word
Word
Word
Word
Word
Address
Address
Address
Address
Address
00 to 07 00 to FF hex
08 to 15 00 to FF hex
12
08 and
09
00 to 07 00 hex: 256 bytes
08 to 11 07 hex: Serial PLC Link
00 to 07 00 hex: Standard setting
00 to 03 0 to 7 hex
Bits
Bits
Bits
Bits
Bits
Default: 00 hex
Default: 00 hex
0: Don’t add start code
1: Add start code
Default: 0
00: Don’t add end code
and use number of
received bytes setting
01: Add end code
11: Add CR+LF
Default: 00
01 to FF hex: 1 to 255
Default: 00 hex
Slave (Polled Unit)
Default: 00 hex
Default: 00 hex
Default: 0 hex
Settings
Settings
Settings
Settings
Settings
The frame format for
no-protocol commu-
nications data (mes-
sages) can be
specified.
Specifies whether
the frame format for
no-protocol commu-
nications is speci-
fied.
Specifies the data length to send and
receive for no-protocol communica-
tions. The start code and end code are
not included in the data length.
This setting is valid only when bits 08
and 09 of +165 are set to 00.
The default setting for each TXD(236)/
RXD(235) instruction is 256 bytes. This
setting can be set to 01 to FF to set 255
bytes or less.
This setting determines whether the
RS-232C port will operate in Serial PLC
Link Slave mode or another serial com-
munications mode. Set 07 for Serial
PLC Link Slave Mode.
Only the standard setting of 38,400 can
be used for the Serial PLC Link Slave
Serial Communications Mode.
Sets the unit number of the FQM1 as a
Serial PLC Link Slave.
Function
Function
Function
Function
Function
Specifies the end
code. This setting is
valid when bits 08 to
09 of +165 are set to
01.
Specifies the start
code. This setting is
valid when bit 12 of
+165 is set to 1.
Specifies whether to
add a start code.
Specifies whether to
add an end code.
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
Related flags and
Related flags and
Related flags and
Related flags and
Related flags and
words
words
words
words
words
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
Appendix C
When setting is
When setting is
When setting is
When setting is
When setting is
read
read
read
read
read