AMIS49587C5871RG ON Semiconductor, AMIS49587C5871RG Datasheet - Page 33

IC MODEM PLC 50/60MHZ 28PLCC

AMIS49587C5871RG

Manufacturer Part Number
AMIS49587C5871RG
Description
IC MODEM PLC 50/60MHZ 28PLCC
Manufacturer
ON Semiconductor
Datasheets

Specifications of AMIS49587C5871RG

Baud Rates
Selectable
Interface
SCI
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
28-PLCC
Number Of Transmitters
1
Power Supply Requirement
Single
Package Type
PLCC
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
28
Operating Temperature (max)
70C
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS49587C5871RG
Manufacturer:
ON
Quantity:
3 400
Part Number:
AMIS49587C5871RG
Manufacturer:
ON Semiconductor
Quantity:
10 000
over a RS232 interface. See paragraph Serial Communication Interface Physical Layer Description for a description on
hardware signals and timings.
This document describes how the RS232 frames need to be
composed to:
7.1
The AMIS- -49587 can operate in different configurations:
Figure 29 depicts a typical PLC network with one master and 2 slaves. Each AMIS- -49587 is controlled by an external CPU
CONFIGURE THE AMIS- -49587
AMIS- -49587
AMIS- -49587
to the data served by one or many slaves on the
power line. It collects data from and controls the
slave devices.
the data to the Master.
is used to only listen to the data that comes across
the power line. Only the physical layer frame
correctness is checked (preamble and SSD, see
Figure 34 Power Line Data Frame Structure). When
the frame is correct, it is passed to the external
processor.
command has been passed to the AMIS- -49587 after
reset. No power line communication is possible.
Get status information from the AMIS- -49587
Configure the AMIS- -49587
Send and Receive network data with the
Get performance and data path statistics from
Master or Client configuration: A Master is a client
Slave or Server configuration: A Slave is a server of
Spy or Monitor configuration: Spy or Monitor mode
Not set configuration: No valid configuration
External CPU
layer
LCC
RS232
AMIS49587
MAC
layer
PLC Master or Client
Figure 29. Typical PLC Network Architecture
7 DETAILED SOFTWARE DESCRIPTION
Physical
Layer
AFE
http://onsemi.com
33
subset of commands.
7.2
the status message is retrieved from the AMIS- -49587 by a
hardware event only. To get the status message the serial
driver on the external CPU needs to pull the T_REQ HW pin
low, like described in paragraph Serial Communication
Interface Physical Layer Description.
AMIS- -49587, the T_REQ HW pin should be pulled low to
get a new status message from the MODEM. Only when the
status message indicates that the buffer is not busy, the
command may be send. The AMIS49587 is the master on
the serial interface and needs to be queried to get access to
the bus.
configuration of the AMIS- -49587 (not set, slave, master or
monitor).
Table 35. SERIAL PORT STATUS FRAME LAYOUT
Each mode has its own configuration parameters and
Opposite to all other commands over the serial interface,
Whenever the external controller sends a command to the
The format of the status message depends on the active
PLC Slave or Server
OBTAINING STATUS MESSAGES
PLC Slave or Server
This is the state of the AMIS- -49587 after a
hardware reset or after a reset command has been
sent to it.
START
AFE
AFE
Physical
Physical
Layer
Layer
AMIS49587
AMIS49587
MAC
MAC
layer
layer
RS232
RS232
Status_Data
External CPU
External CPU
layer
layer
LCC
LCC

Related parts for AMIS49587C5871RG