AMIS49587C5871RG ON Semiconductor, AMIS49587C5871RG Datasheet - Page 41

IC MODEM PLC 50/60MHZ 28PLCC

AMIS49587C5871RG

Manufacturer Part Number
AMIS49587C5871RG
Description
IC MODEM PLC 50/60MHZ 28PLCC
Manufacturer
ON Semiconductor
Datasheets

Specifications of AMIS49587C5871RG

Baud Rates
Selectable
Interface
SCI
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
28-PLCC
Number Of Transmitters
1
Power Supply Requirement
Single
Package Type
PLCC
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
28
Operating Temperature (max)
70C
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS49587C5871RG
Manufacturer:
ON
Quantity:
3 400
Part Number:
AMIS49587C5871RG
Manufacturer:
ON Semiconductor
Quantity:
10 000
Table 42. NON CHANGEABLE PARAMETERS AFTER AMIS 49587 IS SET
Table 43. WriteConfig ERROR CODES
7.3.5 AccessDB_Request
subcommands to read from the data base.
frame.
chapter.
R_CONF_TX_DATA_PRE_SLOT_SEL
R_CONF→MODE
R_CONF→BAUDRATE
R_CONF→MAINS_FREQ
<STX>
Note that although the name of the AccessDB_Request command suggests only write operations are possible, there are
Each AccessDB_Request command is answered by the MODEM with either a AccessDB_Confirm or AccessDB_Error
For better readability, the AccessDB_Confirm frames and explanation are listed here and not grouped into a separate
0x07 + length of
data (Length)
ERR_ILLEGAL_INITIATOR_MAC_ADR
ERR_ILLEGAL_LOCAL_MAC_ADR
ERR_ILLEGAL_DATA_COMMAND
ERR_UNAVAILABLE_COMMAND
Field
ERR_UNAVAILABLE_MODE
Error Identifier
External CPU
Figure 33. Sequence Diagram for AccessDB_Request
0x41 (AccessDB_Request)
3 bits (b5 to b3)
2 bits (b2,b1)
[Data fields can’t be changed now]
1 bit (b7)
1 bit (b0)
Length
AccessDB_Request (0x41)
[Data fields can be changed]
AccessDB_Confirm (0x42)
AccessDB_Error (0x43)
http://onsemi.com
41
Value
xxx
xx
x
x
Data Field Identifier (Table44)
AMIS49587
Command
Interpreter
Error_Code
Description
21h
22h
23h
24h
25h
No action
No action
No action
No action
Data
CHK