AMIS49587C5872RG ON Semiconductor, AMIS49587C5872RG Datasheet - Page 21

IC MODEM PLC 50/60MHZ 52QFN

AMIS49587C5872RG

Manufacturer Part Number
AMIS49587C5872RG
Description
IC MODEM PLC 50/60MHZ 52QFN
Manufacturer
ON Semiconductor
Datasheet

Specifications of AMIS49587C5872RG

Baud Rates
Selectable
Interface
SCI
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
52-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS49587C5872RG
Manufacturer:
Seagate
Quantity:
1 000
6.1.4 Clock Generator and Timer
of timing signals used for the synchronization and interrupt
generation. The timing generation has a fixed repetition rate
which corresponds to the length of a physical subframe. (see
paragraph Send and Receive network data).
CHIP_CLK is the output of the PLL and 8 times the bit rate on the physical interface. See also paragraph 50/60 Hz PLL
BIT_CLK is active at counter values 0,8,16, .. 2872 and inactive at all other counter values. This signal is used to indicate
the transmission of a new bit.
BYTE_CLK is active at counter values 0,64,128, .. 2816 and inactive at all other counter values. This signal is used to indicate
the transmission of a new byte.
FRAME_CLK is active at counter values 0 and inactive at all other counter values. This signal is used to indicate the
transmission or reception of a new frame.
PRE_BYTE_CLK is a signal which is 8 CHIP_CLK sooner than BYTE_CLK. This signal is used as an interrupt for the
internal microcontroller and indicates that a new byte for transmission must be generated.
PRE_FRAME_CLK is a signal which is 8 CHIP_CLK sooner than FRAME_CLK. This signal is used as an interrupt for
the internal microcontroller and indicates that a new frame will start at the next FRAME_CLK.
PRE_SLOT is logic 1 between the rising edge of PRE_FRAME_CLK and the rising edge of FRAME_CLK. This signal can
be provided at the digital output pin TX_DATA_PRE_SLOT when R_CONF[7] = 0 (See paragraph WriteConfigRequest, field
TX_DATA_PRE- -SLOT_SEL) and can be used by the external host controller to synchronize its software with the
FRAME_CLK of AMIS- -49587.
PRE_FRAME_CLK
The CHIP_CLK and f
PRE_BYTE_CLK
FRAME_CLK
PRE_SLOT
BYTE_CLK
R_CHIP_CNT
CHIP_CLK
BIT_CLK
2871 2872
CLK
are used to generate a number
Start of the physical subframe
2879
0
Figure 16. Timing Signals
1
http://onsemi.com
2
21
3
mode. When AMIS- -49587 switches from receive to
transmit and back from transmit to receive, the
R_CHIP_CNT counter value is maintained. As a result all
timing signals for receive and transmit have the same
relative timing. The following timing signals are defined as:
The timing generator is the same for transmit and receive
4
5
6
7
8
9
63
64
65

Related parts for AMIS49587C5872RG