SCAN12100TYA/NOPB National Semiconductor, SCAN12100TYA/NOPB Datasheet - Page 24

IC SERIAL/DESERIAL CPRI 100-TQFP

SCAN12100TYA/NOPB

Manufacturer Part Number
SCAN12100TYA/NOPB
Description
IC SERIAL/DESERIAL CPRI 100-TQFP
Manufacturer
National Semiconductor
Series
SCANr
Datasheet

Specifications of SCAN12100TYA/NOPB

Function
Serializer/Deserializer
Data Rate
614.4Mbps
Input Type
LVTTL/LVCMOS
Output Type
LVTTL, LVCMOS
Number Of Inputs
10
Number Of Outputs
10
Voltage - Supply
1.8 V ~ 3.3 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
100-TQFP Exposed Pad, 100-eTQFP, 100-HTQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SCAN12100TYA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCAN12100TYA/NOPB
Manufacturer:
Texas Instruments
Quantity:
10 000
www.national.com
Address
Register Description
The SCAN12100 implements the device ID of 61 (0x3D.)
Other registers defined by 802.3ae-2002 are not implement-
ed in SCAN12100. The SCAN12100 has a rich MDIO register
set to allow the chip to be controlled and monitored through
software. Certain functions such as BIST and delay calibra-
tion are only accessible through MDIO.
pins tied to a logic high.
1A-1D
16-17
(hex)
10
11
12
13
14
15
18
19
1E
1F
20
21
22
23
24
25
26
27
28
29
C
D
A
B
E
F
0
1
2
3
4
5
6
7
8
9
Note: The Default register values assume 614.4 mbps operation with the RESETB, RXCLKMODE, TXPWDN, and RXPWDN
Name
RESERVED
POWERDOWN
OUI
OUI Revision
RESET
Rx Equalization
Tx De-Emphasis
LOOPBACK
MDIO
BIST
Speed Mode
BIST Status
RESERVED
DCM Start
OUI Duplicate
OUI Rev. Duplicate
LOF
LOS
Rx Lock
Loss of Clock
PLL Status
Hyperframe Length
DCM Trigger
Reserved
Hyperframe Tuning
Reserved
T14 Lower
T14 Upper
Toffset Lower
Toffset Upper
Tser Lower
Tser Upper
Tdes Lower
Tdes Upper
Tin-out Lower
Tin-out Upper
Tout-in Lower
Tout-in Upper
RW/Pin OW Selects CPRI speed mode.
Access
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RO
RO
RC
RO
RC
RO
RC
RO
RO
RC
RC
RC
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Description
Reserved.
Transmiter and Receiver POWERDOWN control.
OUI.
OUI, Device Product and Revision information.
Transmiter and Receiver RESET control.
CPRI LOF (Loss of Frame) bypass and Receiver EQ control.
Hyperframe size and Transmitter De-Emphasis control.
Selects Normal, Line and Local Loopback.
Required by MDIO.
Pattern and Enable control for Trasmit and Receive BIST.
BIST status information.
Reserved.
Initiates or restarts Delay Calibration Measurement.
Duplicate of Register Address 2.
Duplicate of Register Address 3.
CPRI Loss of Frame (LOF) counter.
CPRI Loss of Sync (LOS) counter.
Receiver Loss of Lock (LOCKB) counter.
Loss of Transmit and/or Receive clock.
Tx and Rx PLL status.
Programmable Hyperframe Length control.
Delay Calibration Trigger pattern.
Reserved.
Programmable Hyperframe size and DCM enable
Reserved.
T14 Measurement.
T14 Measurement.
Toffset Measurement.
Toffset Measurement.
Tser Measurement.
Tser Measurement.
Tdes Measurement.
Tdes Measurement.
Tin-out Measurement.
Tin-out Measurement.
Tout-in Measurement.
Tout-in Measurement.
24
The type of registers used in SCAN12100 are RW, RC, RO,
and WC. RW is a read and write register. RC is a read and
clear register. Upon reading the value of the RC register
through MDIO, the register will reset its value. WC is a write
and clear register. Write and clear registers are used for reset
operations. A re-read of the WC register is necessary to verify
the register has been cleared.

Related parts for SCAN12100TYA/NOPB