PCA9541APW/01,112 NXP Semiconductors, PCA9541APW/01,112 Datasheet - Page 12

IC I2C 2:1 SELECTOR 16-TSSOP

PCA9541APW/01,112

Manufacturer Part Number
PCA9541APW/01,112
Description
IC I2C 2:1 SELECTOR 16-TSSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA9541APW/01,112

Package / Case
16-TSSOP
Applications
2-Channel I²C Multiplexer
Interface
I²C, SMBus
Voltage - Supply
2.3 V ~ 5.5 V
Mounting Type
Surface Mount
Maximum Operating Frequency
400 KHz
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-4938-5
935289365112
NXP Semiconductors
PCA9541A_3
Product data sheet
Table 9.
As a master reads its Control Register
[1]
Table 10.
[1]
Switch to the new channel is done when the master initiating the switch request sends a
STOP command to the PCA9541A.
If either master wants to change the connection of the downstream channel, it needs to
write to its Control Register (Reg#01), and then send a STOP command because an
update of the connection to the downstream according to the values in the two internal
Control Registers happens only on a STOP command. Writing to one control register
followed by a STOP condition on the other master's channel will not cause an update to
the downstream connection.
When both masters request a switch to their own channel at the same time, the master
who last wrote to its Control Register before the PCA9541A receives a STOP command
wins the switching sequence. There is no arbitration performed.
The Auto Increment feature (AI = 1) allows to program the PCA9541A in 4 bytes:
Start
111A3A2A1A0 + 0
00010000
Data Reg#00
Data Reg#01
Stop
NMYBUS
0
1
0
1
NBUSON
0
1
0
1
MYBUS and NMYBUS is an exclusive-OR type function where:
Equal values (00b or 11b) means that the master reading its Control Register has control of the bus.
Different values (01b or 10b) means that the master reading its Control Register does not have control of
the bus.
BUSON and NBUSON is an exclusive-OR type function where:
Equal values (00b or 11b) means that the connection between the upstream and the downstream channels
is off.
Different values (01b or 10b) means that the connection between the upstream and the downstream
channels is on.
[1]
[1]
MYBUS and NMYBUS truth table
BUSON and NBUSON truth table
MYBUS
0
0
1
1
BUSON
0
0
1
1
[1]
[1]
PCA9541 Address + Write
Select Reg#00 with AI = 1
Interrupt Enable Register data
Control Register data
Rev. 03 — 16 July 2009
Slave channel
The master reading this combination has control of the bus.
The master reading this combination does not have control of the bus.
The master reading this combination does not have control of the bus.
The master reading this combination has control of the bus.
Slave channel
off
on
on
off
2-to-1 I
2
C-bus master selector with interrupt logic and reset
PCA9541A
© NXP B.V. 2009. All rights reserved.
12 of 41

Related parts for PCA9541APW/01,112