RC28F128J3D75B Numonyx - A DIVISION OF MICRON SEMICONDUCTOR PRODUCTS, INC., RC28F128J3D75B Datasheet - Page 51

IC FLASH 128MBIT 75NS 64EZBGA

RC28F128J3D75B

Manufacturer Part Number
RC28F128J3D75B
Description
IC FLASH 128MBIT 75NS 64EZBGA
Manufacturer
Numonyx - A DIVISION OF MICRON SEMICONDUCTOR PRODUCTS, INC.
Series
-r
Datasheet

Specifications of RC28F128J3D75B

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
128M (16Mx8, 8Mx16)
Speed
75ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-EZBGA
Lead Free Status / Rohs Status
Contains lead / RoHS non-compliant
Other names
872763
872763TR
872763TR
RC28F128J3D75 872763
RC28F128J3D75B
RC28F128J3D75BTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RC28F128J3D75B
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Numonyx™ Embedded Flash Memory (J3 v D, Monolithic)
Figure 21: Byte/Word Program Flowchart
December 2007
316577-06
FULL STATUS CHECK PROCEDURE
Program Complete
Check if Desired
Write Data and
Register Data
(See Above)
Read Status
Read Status
Successful
Write 40H,
Full Status
Byte/Word
Byte/Word
Program
Address
Address
Register
SR.7 =
SR.3 =
SR.1 =
SR.4 =
Start
0
0
0
1
1
1
1
0
Voltage Range Error
Device Protect Error
Programming Error
1. Toggling OE# (low to high to low) updates the status register. This
can be done in place of issuing the Read Status Register command.
Repeat for subsequent programming operations.
SR full status check can be done after each program operation, or
after a sequence of programming operations.
Write FFH after the last program operation to place device in read
array mode.
Toggling OE# (low to high to low) updates the status register. This can
be done in place of issuing the Read Status Register command.
Repeat for subsequent programming operations.
SR.4, SR.3 and SR.1 are only cleared by the Clear Status Register
command in cases where multiple locations are programmed before
full status is checked.
If an error is detected, clear the status register before attempting retry
or other error recovery.
Operation
Operation
Standby
Standby
Standby
Standby
(Note 1)
Write
Write
Read
Bus
Bus
Word Program
Setup Byte/
Command
Command
Byte/Word
Program
Data = 40H
Addr = Location to Be Programmed
Data = Data to Be Programmed
Addr = Location to Be Programmed
Status Register Data
Check SR.7
1 = WSM Ready
0 = WSM Busy
Check SR.3
1 = Programming to Voltage Error
Check SR.1
1 = Device Protect Detect
Only required for systems
implemeting lock-bit configuration.
Check SR.4
1 = Programming Error
Detect
RP# = V
IH
Comments
Comments
, Block Lock-Bit Is Set