Responses
Example of Using an Explicit Message
If reading proceeds correctly, the response is stored as follows.
DM00015
DM00016
DM00017
DM00018
DM00019
DM00015
Word
00 00
XX XX
XX XX
28 01
00 B4
B4 8E
Contents
(Hex)
Explicit message transmission command code= 28 01
Hex
End code (0000 Hex: normal end)
(data length after DM00018)
"Receiving data reading" response service code = 8E
Hex
in the order upper byte, lower byte.
Number of bytes received
Transmit service 2 byte = 00B4 Hex,
Transmit service 1 byte = B4 Hex
The data received at port 1 of the DRT1-232C is stored
Definition