CY2308SC-3T Cypress Semiconductor Corp, CY2308SC-3T Datasheet - Page 14

CY2308SC-3T

Manufacturer Part Number
CY2308SC-3T
Description
Manufacturer
Cypress Semiconductor Corp
Type
Zero Delay PLL Clock Driverr
Datasheet

Specifications of CY2308SC-3T

Number Of Elements
1
Supply Current
45mA
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
0C to 70C
Package Type
SOIC
Output Frequency Range
10 to 133.3MHz
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temperature Classification
Commercial
Pin Count
16
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY2308SC-3T
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Document History Page
Document Number: 38-07146 Rev. *H
Document Title: CY2308 3.3V Zero Delay Buffer
Document Number: 38-07146
Rev.
*A
*B
*C
*D
*E
*G
*H
*F
**
1344343
2568575
2632364
2673353
121832
235854
310594
110255
118722
ECN
KVM/PYRS
KVM/VED
Orig. of
Change
AESA
KVM
RGL
RGL
RGL
SZV
RBI
Submission
12/17/01
10/31/02
12/14/02
06/24/04
02/09/05
08/20/07
09/19/08
01/08/09
03/13/09
Date
Changed from Specification number: 38-00528 to 38-07146
Added Note 1 in page 2.
Power up requirements added to Operating Conditions Information
Added Pb-Free Devices
Removed obsolete parts in the ordering information table
Specified typical value for cycle-to-cycle jitter
Brought the Ordering Information Table up to date: removed three obsolete parts
and added two parts
Changed titles to tables that are specific to commercial and industrial temperature
ranges
Updated template. Added Note “Not recommended for new designs.”
Changed IDD (PD mode) from 12.0 to 25.0 μA for Commercial and Industrial
Temperature Devices
Deleted Duty Cycle parameters for F
Removed CY2308SI-4, CY2308SI-4T and CY2308SC-5HT.
Corrected TSSOP package size (from 150 mil to 4.4 mm) in Ordering Information
table
Reverted IDD (PD mode) and Duty Cycle parameters back to the values in
revision *E:
Changed IDD (PD mode) from 25 to 12 μA for commercial temperature devices
Added Duty Cycle parameters for F
devices.
Description of Change
out
out
< 50 MHz for commercial and industrial
< 50 MHz
Page 14 of 15
CY2308
[+] Feedback

Related parts for CY2308SC-3T