TDA7563B STMicroelectronics, TDA7563B Datasheet - Page 17

no-image

TDA7563B

Manufacturer Part Number
TDA7563B
Description
IC AMP QUAD MULTIFUNC FLEXIWATT2
Manufacturer
STMicroelectronics
Type
Class ABr
Datasheet

Specifications of TDA7563B

Output Type
4-Channel (Quad)
Max Output Power X Channels @ Load
75W x 4 @ 2 Ohm
Voltage - Supply
8 V ~ 18 V
Features
I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting Type
Through Hole
Package / Case
27-Flexiwatt (bent and staggered leads)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA7563B
Manufacturer:
ST
0
Part Number:
TDA7563B
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B DD
Manufacturer:
ST
0
Part Number:
TDA7563B DD
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B-DB
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B-DD
Manufacturer:
ST
0
Part Number:
TDA7563B-DD
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B/TDA7563
Manufacturer:
ST
0
Part Number:
TDA7563B@@@@@
Manufacturer:
ST
0
Part Number:
TDA7563BH
Manufacturer:
FREESCALE
Quantity:
150
Part Number:
TDA7563BH
Manufacturer:
ST
Quantity:
20 000
TDA7563B
4.3
4.4
Output DC offset detection
Any DC output offset exceeding ±2 V are signalled out. This inconvenient might occur as a
consequence of initially defective or aged and worn-out input capacitors feeding a DC
component to the inputs, so putting the speakers at risk of overheating.
This diagnostic has to be performed with low-level output AC signal (or Vin = 0).
The test is run with selectable time duration by microprocessor (from a "start" to a "stop"
command):
Excess offset is signalled out if persistent throughout the assigned testing time. This feature
is disabled if any overloads leading to activation of the short-circuit protection occurs in the
process.
AC diagnostic
It is targeted at detecting accidental disconnection of tweeters in 2-way speaker and, more
in general, presence of capacitively (AC) coupled loads.
This diagnostic is based on the notion that the overall speaker's impedance (woofer +
parallel tweeter) will tend to increase towards high frequencies if the tweeter gets
disconnected, because the remaining speaker (woofer) would be out of its operating range
(high impedance). The diagnostic decision is made according to peak output current
thresholds, as follows:
To correctly implement this feature, it is necessary to briefly provide a signal tone (with the
amplifier in "play") whose frequency and magnitude are such to determine an output current
higher than 500 mApk with in normal conditions and lower than 250 mApk should the
parallel tweeter be missing.
The test has to last for a minimum number of 3 sine cycles starting from the activation of the
AC diagnostic function IB2 < D2 > 0 up to the I
To confirm presence of tweeter, it is necessary to find at least 3 current pulses over 500 mA
over all the measuring period, else an "open tweeter" message will be issued.
The frequency / magnitude setting of the test tone depends on the impedance
characteristics of each specific speaker being used, with or without the tweeter connected
(to be calculated case by case). High-frequency tones (> 10 kHz) or even ultrasonic signals
are recommended for their negligible acoustic impact and also to maximize the impedance
module's ratio between with tweeter-on and tweeter-off.
Figure 27
relevant diagnostic fields.
This feature is disabled if any overloads leading to activation of the short-circuit protection
occurs in the process.
Start = Last reading operation or setting IB1 - D5 - (offset enable) to 1
Stop = Actual reading operation
shows the load impedance as a function of the peak output voltage and the
Iout > 500 mApk = normal status
Iout < 250 mApk = open tweeter
Doc ID 12733 Rev 3
2
C reading of the results (measuring period).
Diagnostics functional description
17/33

Related parts for TDA7563B