Specifications of AT89C51CC02
Flash (kbytes)
16 Kbytes
Max. Operating Frequency
40 MHz
Cpu
8051-12C
Max I/o Pins
20
Uart
1
Can
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
62.5
Sram (kbytes)
0.5
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
3.0 to 5.5
Timers
4
Isp
UART/CAN
Watchdog
Yes
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
Atmel
Quantity:
972
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
AT89C51CC02CA-TISUM
Manufacturer:
Atmel
Quantity:
1 492
Company:
Part Number:
AT89C51CC02CA-UM
Manufacturer:
AD
Quantity:
10
Company:
Part Number:
AT89C51CC02UA-RATUM
Manufacturer:
Atmel
Quantity:
1 845
Company:
Part Number:
AT89C51CC02UA-UM
Manufacturer:
NEDI
Quantity:
4
Boot Process
Software Boot Process
Example
Figure 19. Hardware Boot Process Algorithm
Application-
Programming-Interface
48
AT/T89C51CC02
Application
in FM0
ENBOOT = 0
PC = 0000h
Many algorithms can be used for the software boot process. Below are descriptions of
the different flags and Bytes.
Boot Loader Jump bit (BLJB):
- This bit indicates if on RESET the user wants to jump to this application at address
@0000h on FM0 or execute the boot loader at address @F800h on FM1.
- BLJB = 0 (i.e. bootloader FM1 executed after a reset) is the default Atmel factory pro-
gramming.
-To read or modify this bit, the APIs are used.
Boot Vector Address (SBV):
- This byte contains the MSB of the user boot loader address in FM0.
- The default value of SBV is FCh (no user boot loader in FM0).
- To read or modify this byte, the APIs are used.
Extra Byte (EB) & Boot Status Byte (BSB):
- These Bytes are reserved for customer use.
- To read or modify these Bytes, the APIs are used.
Several Application Program Interface (API) calls are available for use by an application
program to permit selective erasing and programming of Flash pages. All calls are made
by functions.
All these APIs are described in detail in the following documents on the Atmel web site.
–
–
Datasheet Bootloader CAN T89C51CC02.
Datasheet Bootloader UART T89C51CC02.
Bootloader
in FM1
BLJB == 0
RESET
?
ENBOOT = 1
PC = F800h
bit ENBOOT in AUXR1 Register
Is Initialized with BLJB Inverted.
Example, if BLJB=0, ENBOOT
is set (=1) during reset, thus the
bootloader is executed after the
reset.
4126L–CAN–01/08