AT89LP51ID2 Atmel Corporation, AT89LP51ID2 Datasheet - Page 137

no-image

AT89LP51ID2

Manufacturer Part Number
AT89LP51ID2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89LP51ID2

Flash (kbytes)
64 Kbytes
Max. Operating Frequency
20 MHz
Cpu
8051-1C
Max I/o Pins
42
Spi
1
Twi (i2c)
1
Uart
1
Adc Channels
7
Adc Resolution (bits)
10
Adc Speed (ksps)
153.8
Sram (kbytes)
2.25
Eeprom (bytes)
4096
Self Program Memory
API
Operating Voltage (vcc)
2.4 to 5.5
Timers
4
Isp
SPI/OCD/UART
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89LP51ID2-20AAU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP51ID2-20AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP51ID2-20JU
Manufacturer:
Atmel
Quantity:
10 000
19.1
19.1.1
19.1.2
19.1.3
3714A–MICRO–7/11
Data Transfer and Frame Format
Transferring Bits
START and STOP Conditions
Address Packet Format
Each data bit transferred on the TWI bus is accompanied by a pulse on the clock line. The level
of the data line must be stable when the clock line is high. The only exception to this rule is for
generating start and stop conditions.
Figure 19-2. Data Validity
The Master initiates and terminates a data transmission. The transmission is initiated when the
Master issues a START condition on the bus, and it is terminated when the Master issues a
STOP condition. Between a START and a STOP condition, the bus is considered busy, and no
other Master should try to seize control of the bus. A special case occurs when a new START
condition is issued between a START and STOP condition. This is referred to as a REPEATED
START condition, and is used when the Master wishes to initiate a new transfer without relin-
quishing control of the bus. After a REPEATED START, the bus is considered busy until the next
STOP. This is identical to the START behavior, and therefore START is used to describe both
START and REPEATED START for the remainder of this data sheet, unless otherwise noted.
As depicted below, START and STOP conditions are signalled by changing the level of the SDA
line when the SCL line is high.
Figure 19-3. START, REPEATED START, and STOP Conditions
All address packets transmitted on the TWI bus are nine bits long, consisting of seven address
bits, one READ/WRITE control bit and an acknowledge bit. If the READ/WRITE bit is set, a read
operation is to be performed, otherwise a write operation should be performed. When a slave
recognizes that it is being addressed, it should acknowledge by pulling SDA low in the ninth SCL
(ACK) cycle. If the addressed Slave is busy, or for some other reason can not service the Mas-
SDA
SCL
START
SDA
SCL
AT89LP51RD2/ED2/ID2 Preliminary
Data Stable
STOP START
Data Change
Data Stable
REPEATED START
STOP
137