ST92124V1Q-Auto STMicroelectronics, ST92124V1Q-Auto Datasheet - Page 425

no-image

ST92124V1Q-Auto

Manufacturer Part Number
ST92124V1Q-Auto
Description
8-bit MCU for automotive
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST92124V1Q-Auto

Internal Memory
Single Voltage FLASH up to 256 Kbytes, RAM up to 8Kbytes, 1K byte E3 TM (Emulated EEPROM)
Minimum Instruction Time
83 ns (24 MHz int. clock)
KNOWN LIMITATIONS (Cont’d)
During reset, the risk of power consumption in the
input stage due to floating inputs is avoided by a
design feature.
However, if the application requires pull-ups
during reset (for instance, in order to send known
logic values to external devices), external pull-ups
must be provided. When the I/O port outputs a
zero, there will be some additional power con-
sumption as these external pull-ups are not
switched off.
These ports behave in the same way following an
external, watchdog or software reset.
13.8.2 High Drive I/Os when BSZ=1
Description
If the BSZ bit in the EMR1 register (bit 1 of R245,
page 21) is set so as to use high-drive output
buffers for P4[7:6] and P6[5:4], all I/O ports as well
as AS, DS and RW will also use high-drive output
buffers.
Impact On Application
P0[7:0], AS, DS and RW have the same V
rameter value as P6[5:4].
P0[7:0]-P2[3:2], AS, DS and RW have the same
V
P6[5:4].
These I/Os using high-drive output buffers will
generate more noise than those using the
standard low-noise output buffers.
13.8.3 ADC PARASITIC DIODE
Description
A parasitic diode is present between an ADC input
and AV
As described in the datasheet, the user has the
possibility to switch off AV
the ADC to save power consumption. However, if
AV
present on the Input Port, an increase in power
consumption can occur.
OL
DD
and I
is connected to ground and a voltage is
DD
IO
.
parameter values as the P4[7:6] and
DD
when he switches off
OH
pa-
ST92124xxx-Auto/150xxxxx-Auto/250xxxx-Auto
The Input Port affected by this diode is the one
pointed to by the analog multiplexer of the ADC, if
the port is set up as AF analog input. When the
ADC is stopped, the multiplexer points to the first
input to be converted in a scan (i.e. the channel
pointed to by the SC[3:0] bits).
Workaround
In order to avoid this problem, the I/O connected to
the ADC has to be set up in any mode except AF
analog input (i.e. any combination of PxC2.. PxC0
except 111).
1. Deprogram analog input mode from the I/O port
2. Next, switch off the A/D Converter.
The current in AV
logic levels on the analog inputs, and whatever the
voltage level applied to AV
V
13.8.4
INJECTION CURRENT
Description
If a negative current is injected to an input pin (i.e.
input signal voltage below -0.3V), a part of this cur-
rent will be drawn from the adjacent I/Os. The fol-
lowing curve quantifies this current:
DD
which is pointed to by the SC[3:0] bits (start
conversion channel, b7..b4 of CLR1).
For example the I/O can be reprogrammed as
an open drain output, with the data at 1. The
high impedance of the output stage then
avoids a conflict with the external voltage
source. In order to avoid potential power con-
sumption in the input buffer of this I/O,
depending on the external voltage applied to
the pin, it is wise to set the 'start conversion
channel' to a channel which carries levels
below 800 mV or above (V
Another possibility is to modify the SC[3:0]
bits so that they point to an I/O Port which is
not used as an analog input.
).
ADC
ACCURACY
DD
will be zero, whatever the
DD
DD
VS.
(between 0 and
- 800 mV).
NEGATIVE
425/430