TSS463C ATMEL Corporation, TSS463C Datasheet - Page 23

no-image

TSS463C

Manufacturer Part Number
TSS463C
Description
Van Data Link Controller With Serial Interface
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSS463C
Manufacturer:
ATMEL
Quantity:
8
Part Number:
TSS463C
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
TSS463C-E9
Manufacturer:
ST
Quantity:
50
Part Number:
TSS463C-E9
Manufacturer:
ATMEL
Quantity:
3
Part Number:
TSS463C-E9
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
TSS463C-TERZ-9
Manufacturer:
ATMEL
Quantity:
101
Internal Operations
Digital Filtering
Transition Analyses
7601B–AUTO–02/06
Status bits give permanent information on the diagnosis performed, whatever the pro-
grammed operating mode. This is encoded over three bits: Sa, Sb and Sc.
Table 3. Status Bits: Sa and Sb
The only way to reset this status bit is through the RI signal or a general reset.
If several spurious pulses occur during one bit, the diagnosis for defective conductor
may be corrupted. To avoid such errors, digital filters are implemented.
Filtering operation is based on sampling of the comparator output signals. A transition is
taken into account only if it is observed over five samples (1/16
These analyses are continuously done on the effective edges on comparators after digi-
tal filtering.
Sa
Sa and Sb bits indicate the four possible states of the VAN bus.
Sc: As soon as one of the three inputs (RXD2, RXD1, RXD0) differs from the others
in the input comparison analysis performs by the diagnosis system, Sc is set.
Asynchronous diagnosis
The asynchronous diagnosis is done by comparing the number of edges on DATA
and DATA.
If four edges are detected on one input and no edges on the other during the same
period, the second input is considered faulty and the diagnosis mode will change to
one of the degraded modes.
Synchronous diagnosis
The synchronous diagnosis counts the number of edges on the data input
connected to the reception logic during one SDC period.
If there are less than four edges during one SDC period, the diagnosis mode will
change to the major error mode.
0
0
1
1
Sb
0
1
0
1
Status
Status
Status
Status
Mode
Mode
Mode
Mode
Fault
Fault
Fault
Fault
Communication
Nominal
No fault on VAN bus
Differential communication on DATA and DATA
Degraded on DATA
Fault on DATA
Communication on DATA
Degraded on DATA
Fault on DATA
Communication on DATA
Major error
Fault on DATA and DATA
No communication on DATA and DATA (attempt to communicate
alternatively on DATA then DATA every SDC period)
th
of timeslot).
TSS463C
23